RIVER VIEW MINE safety activity
MSHA violations, accident reports and inspections.
Safety activity
Communication between shaft stations and hoist room.
30 CFR 75.1402
Cable fittings; suitability.
30 CFR 75.515
Spot Inspections
103(i) · 10.0 on-site hours reported
Roof control plan.
30 CFR 75.220(a)(1)
Automatic fire sensors and manual actuators; installation; minimum requirements.
30 CFR 75.1107-4(c)
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S)
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S)
Methane monitors.
30 CFR 75.342(a)(4)
Protection from falls of roof, face and ribs.
30 CFR 75.202(a)
Regular Safety and Health Inspection
224.0 on-site hours reported
Spot Inspections
103(i) · 8.0 on-site hours reported
Roof control plan.
30 CFR 75.220(a)(1)
Roof Control Technical Investigation
19.5 on-site hours reported
Electric equipment; examination, testing and maintenance.
30 CFR 75.512
Spot Inspections
103(i) · 8.0 on-site hours reported
Slip or fall of person
Days away from work only
Accident narrative
Employee was using a fiberglass step ladder in an underpass when the legs on the ladder broke causing them to fall to the mine floor resulting in a contusion to left hip/thigh area. Started missing work 9/25/2026.
Slip or fall of person
Days away from work only
Accident narrative
at the first intersection off of the cage the scoop operator slipped on the wet bottom as they turned the corner. The scoop operator fell to the ground landing on their left arm, causing a fracture. Started missing work on 09/10/2026.
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $465.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $465.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $1,431.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $642.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · $209.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $465.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $151.00 proposed penalty
Emergency tethers.
30 CFR 75.1714-6 · $151.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.