ECFR SNAPSHOT / CURRENT THROUGH 2026-08-19

30 CFR 75.604

Permanent splicing of trailing cables.

CHAPTERCHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
PARTPART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES
SUBPARTSubpart G—Trailing Cables

CURRENT PUBLIC TEXT

[Statutory Provisions]

When permanent splices in trailing cables are made, they shall be:

(a) Mechanically strong with adequate electrical conductivity and flexibility;

(b) Effectively insulated and sealed so as to exclude moisture; and

(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.

(d) Made using splice kits accepted or approved by MSHA as flame resistant.

[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]