← Coal-Mac MET, LLC

Coal-Mac MET, LLC safety activity

MSHA violations, accident reports and inspections across the current mine portfolio.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Permissible electric face equipment; maintenance.

    violationRecord 5029903
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.503 · $151.00 proposed penalty

  2. Electric equipment; examination, testing and maintenance.

    violationRecord 5029902
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.512 · Significant and substantial (S&S) · $245.00 proposed penalty

  3. Ventilation controls.

    violationRecord 5029901
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.333(e)(1)(ii) · $151.00 proposed penalty

  4. Permissible electric face equipment; maintenance.

    violationRecord 5060800
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.503 · $151.00 proposed penalty

  5. Drill dust control at underground areas of underground mines.

    violationRecord 5060799
    Eagle Energy Mine No.1 · 4609425

    30 CFR 72.630(b) · $151.00 proposed penalty

  6. Permissible electric face equipment; maintenance.

    violationRecord 5060798
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.503 · $151.00 proposed penalty

  7. Drill dust control at underground areas of underground mines.

    violationRecord 5060797
    Eagle Energy Mine No.1 · 4609425

    30 CFR 72.630(b) · Significant and substantial (S&S) · $883.00 proposed penalty

  8. Water sprinkler systems; general.

    violationRecord 5060796
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.1101-6 · $151.00 proposed penalty

  9. Roof control plan.

    violationRecord 9847571
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.220(a)(1) · $165.00 proposed penalty

  10. Clamping of trailing cables to equipment.

    violationRecord 5060795
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.605 · $151.00 proposed penalty

  11. Permanent splicing of trailing cables.

    violationRecord 5060794
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.604(b) · Significant and substantial (S&S) · $549.00 proposed penalty

  12. Power wires and cables; insulation and protection.

    violationRecord 5060793
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.517 · Significant and substantial (S&S) · $549.00 proposed penalty

  13. Stepping or kneeling on object

    accidentRecord 220252240009
    DEEPWATER SURFACE MINE · 4609105

    Days away from work only

    Accident narrative

    Employee was performing maintenance on a GMC 645 service truck. While in the process of walking around the front of the service truck EE inadvertently stepped on a rock causing EE to "roll" EE's ankle, fracturing the right ankle.

  14. Power wires and cables; insulation and protection.

    violationRecord 5060792
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.517 · Significant and substantial (S&S) · $1,818.00 proposed penalty

  15. Permissible electric face equipment; maintenance.

    violationRecord 5060790
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.503 · $151.00 proposed penalty

  16. Power wires and cables; insulation and protection.

    violationRecord 5060789
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.517 · Significant and substantial (S&S) · $549.00 proposed penalty

  17. Dry chemical devices; capacity; minimum requirements.

    violationRecord 5060788
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.1107-9(a)(1) · $151.00 proposed penalty

  18. Permissible electric face equipment; maintenance.

    violationRecord 5060787
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.503 · $151.00 proposed penalty

  19. Identification check system.

    violationRecord 5060786
    Eagle Energy Mine No.1 · 4609425

    30 CFR 75.1715 · $151.00 proposed penalty

  20. Regular Safety and Health Inspection

    inspectionRecord F015B4E
    Eagle Energy Mine No.1 · 4609425

    110.8 on-site hours reported

  21. Handtools (nonpowered)

    accidentRecord 220252130012
    Eagle Energy Mine No.1 · 4609425

    No dys awy frm wrk,no rstr act

    Accident narrative

    Employee stated EE was helping to strip the red phase lead in the High Line preparing to enter the High Line into the #3 Outby KVA. As EE was stripping the lead EE's knife blade slipped causing a laceration to EE's left thumb. Employee sought medical treatment and received 5 stitches.

  22. Spot Inspection

    inspectionRecord F01337D
    Glenco Load-Out · 4609218

    9.0 on-site hours reported

  23. Special Emphasis Programs

    inspectionRecord F01337C
    Deep Water Prep Plant P-2 · 4609162

    1.5 on-site hours reported

  24. Special Emphasis Programs

    inspectionRecord F01337B
    Glenco Load-Out · 4609218

    1.5 on-site hours reported

  25. Special Emphasis Programs

    inspectionRecord 6322871
    Eagle Energy Mine No.1 · 4609425

    2.0 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.