← Coal Mac East

Coal Mac East safety activity

MSHA violations, accident reports and inspections across the current mine portfolio.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Spot Inspections

    inspectionRecord F0307CA
    Lower War Eagle · 4609319

    103(i) · 0.0 on-site hours reported

  2. Permanent splicing of trailing cables.

    violationRecord 5098028
    Powellton #1 Mine · 4609217

    30 CFR 75.604(b) · Significant and substantial (S&S)

  3. Electric equipment; examination, testing and maintenance.

    violationRecord 5098027
    Powellton #1 Mine · 4609217

    30 CFR 75.512

  4. Additional self-contained self-rescuers (SCSRs).

    violationRecord 5098026
    Powellton #1 Mine · 4609217

    30 CFR 75.1714-4(e)

  5. Electric equipment; examination, testing, and maintenance.

    violationRecord 5134830
    Lower War Eagle · 4609319

    30 CFR 77.502

  6. Mine emergency notification plan.

    violationRecord 5130359
    Lower War Eagle · 4609319

    30 CFR 49.19(b)

  7. Availability of mine rescue teams.

    violationRecord 5130358
    Lower War Eagle · 4609319

    30 CFR 49.12(h)

  8. Short circuit protection; ratings and settings of circuit breakers.

    violationRecord 5134827
    Powellton #1 Mine · 4609217

    30 CFR 75.601-1

  9. Accumulation of combustible materials.

    violationRecord 5134826
    Powellton #1 Mine · 4609217

    30 CFR 75.400

  10. Electric equipment; examination, testing and maintenance.

    violationRecord 5098021
    Powellton #1 Mine · 4609217

    30 CFR 75.512

  11. Mine ventilation plan; submission and approval.

    violationRecord 5098020
    Powellton #1 Mine · 4609217

    30 CFR 75.370(a)(1)

  12. Regular Safety and Health Inspection

    inspectionRecord F022449
    Lower War Eagle · 4609319

    0.0 on-site hours reported

  13. Health Technical Investigation

    inspectionRecord F02EE12
    Lower War Eagle · 4609319

    11.0 on-site hours reported

  14. Spot Inspections

    inspectionRecord F0307C7
    Lower War Eagle · 4609319

    103(i) · 6.0 on-site hours reported

  15. Power wires; support.

    violationRecord 5134822
    Lower War Eagle · 4609319

    30 CFR 75.516

  16. Mine ventilation plan; submission and approval.

    violationRecord 5132897
    Powellton #1 Mine · 4609217

    30 CFR 75.370(a)(1)

  17. Spot Inspection

    inspectionRecord F021D6D
    Lower War Eagle · 4609319

    3.8 on-site hours reported

  18. Installation of high-voltage transmission cables.

    violationRecord 5132890
    Powellton #1 Mine · 4609217

    30 CFR 75.807

  19. Communications facilities; refuge alternatives.

    violationRecord 5132889
    Powellton #1 Mine · 4609217

    30 CFR 75.1600-3(a)(1)

  20. Escapeway maps.

    violationRecord 5132888
    Powellton #1 Mine · 4609217

    30 CFR 75.1505(b)

  21. Regular Safety and Health Inspection

    inspectionRecord F00857B
    Powellton #1 Mine · 4609217

    49.8 on-site hours reported

  22. Spot Inspections

    inspectionRecord F021D6C
    Lower War Eagle · 4609319

    103(i) · 7.3 on-site hours reported

  23. Roof control plan.

    violationRecord 5132886
    Powellton #1 Mine · 4609217

    30 CFR 75.220(a)(1)

  24. Other safeguards.

    violationRecord 5132885
    Powellton #1 Mine · 4609217

    30 CFR 75.1403

  25. Weekly examination.

    violationRecord 5098016
    Lower War Eagle · 4609319

    30 CFR 75.364(g)

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.