← Winchester Peerless Rachel Mine

Winchester Peerless Rachel Mine safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Electric equipment; examination, testing and maintenance.

    violationRecord 5028053

    30 CFR 75.512 · $226.00 proposed penalty

  2. Protection from falls of roof, face and ribs.

    violationRecord 5028052

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  3. Inspection of fire suppression devices.

    violationRecord 5028051

    30 CFR 75.1107-16(b) · $151.00 proposed penalty

  4. Accumulation of combustible materials.

    violationRecord 5028050

    30 CFR 75.400 · $288.00 proposed penalty

  5. Spot Inspections

    inspectionRecord F00C0BC

    103(i) · 5.0 on-site hours reported

  6. Mine ventilation plan; submission and approval.

    violationRecord 5028049

    30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $4,749.00 proposed penalty

  7. Emergency tethers.

    violationRecord 5028048

    30 CFR 75.1714-6 · $151.00 proposed penalty

  8. Power wires and cables; insulation and protection.

    violationRecord 5027639

    30 CFR 75.517 · Significant and substantial (S&S) · $3,448.00 proposed penalty

  9. Mine ventilation plan; submission and approval.

    violationRecord 5027638

    30 CFR 75.370(a)(1) · $755.00 proposed penalty

  10. Mine ventilation plan; submission and approval.

    violationRecord 5027637

    30 CFR 75.370(a)(1) · $755.00 proposed penalty

  11. Storage of liquefied and nonliquefied compressed gas cylinders; requirements.

    violationRecord 5027636

    30 CFR 75.1106-3(a)(2) · $226.00 proposed penalty

  12. Non-Injury Accident Investigation

    inspectionRecord F00C0BA

    10.5 on-site hours reported

  13. Violation — cited standard not reported

    violationRecord 9847603
  14. Fall of roof or back

    accidentRecord 220261900005

    Accident only

    Accident narrative

    An unintentional roof fall occurred at 3 South Mains, #8 Break, in the #7 Entry. The fall is approx. 5-6 ft high, 12 ft wide, and 15-20 ft long. No injuries, entrapments, ventilation disruption, or blocked travelways occurred. The area was dangered off and the lifeline rerouted.

  15. Protection from falls of roof, face and ribs.

    violationRecord 5028047

    30 CFR 75.202(a) · $755.00 proposed penalty

  16. Electric equipment; examination, testing and maintenance.

    violationRecord 5028046

    30 CFR 75.512 · $226.00 proposed penalty

  17. Regular Safety and Health Inspection

    inspectionRecord F0058BB

    474.8 on-site hours reported

  18. Spot Inspections

    inspectionRecord F022D78

    103(i) · 6.5 on-site hours reported

  19. Spot Inspections

    inspectionRecord F022D74

    103(i) · 7.5 on-site hours reported

  20. Permissible exposure level.

    violationRecord 5028031

    30 CFR 62.130(a) · Significant and substantial (S&S) · $1,037.00 proposed penalty

  21. Permissible exposure level.

    violationRecord 5028030

    30 CFR 62.130(a) · Significant and substantial (S&S) · $1,037.00 proposed penalty

  22. Water sprinkler systems; fire warning devices at belt drives.

    violationRecord 5090061

    30 CFR 75.1101-10 · $151.00 proposed penalty

  23. Machinery

    accidentRecord 220261590003

    No dys awy frm wrk,no rstr act

    Accident narrative

    Employee was roof bolting in #2 Entry when a rock dislodged from the mine roof while drilling, struck EE's hand, and caught EE's left ring finger between the rock and drill pot. Employee was evaluated at Boone Memorial, diagnosed with a fracture, and returned to work 6/4/2026 with no restrictions. No Days Lost

  24. Methane monitors.

    violationRecord 5028029

    30 CFR 75.342(a)(4) · $245.00 proposed penalty

  25. Permanent splicing of trailing cables.

    violationRecord 5028028

    30 CFR 75.604(b) · $549.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.