← Stonecoal Branch Mine No. 2

Stonecoal Branch Mine No. 2 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Installation of high-voltage transmission cables.

    violationRecord 5093054

    30 CFR 75.807 · $1,219.00 proposed penalty

  2. Regular Safety and Health Inspection

    inspectionRecord F013A0E

    480.5 on-site hours reported

  3. Handling of materials

    accidentRecord 220253170114

    No dys awy frm wrk,no rstr act

    Accident narrative

    The employee was setting standing support when EE turned EE's back on a standing unwedged timber to grab EE's hammer. The unwedged timber fell, striking EE in the head.

  4. Spot Inspection

    inspectionRecord F00CDC0

    14.5 on-site hours reported

  5. Spot Inspection

    inspectionRecord 7049070

    9.8 on-site hours reported

  6. Protection from falls of roof, face and ribs.

    violationRecord 9837638

    30 CFR 75.202(a) · Significant and substantial (S&S) · $9,757.00 proposed penalty

  7. Fall of roof or back

    accidentRecord 220252660013

    Accident only

    Accident narrative

    An unplanned roof fall at or above the anchorage zone occurred on the active working no. 3 section, 2 breaks inby spad no. 6687.

  8. Non-Injury Accident Investigation

    inspectionRecord 7049071

    4.0 on-site hours reported

  9. Violation — cited standard not reported

    violationRecord 9837637
  10. Automatic fire warning devices; actions and response.

    violationRecord 9837173

    30 CFR 75.1103-5(a) · $366.00 proposed penalty

  11. Electrical Technical Investigation

    inspectionRecord F00A100

    4.5 on-site hours reported

  12. Electric equipment; examination, testing and maintenance.

    violationRecord 9837172

    30 CFR 75.512 · $697.00 proposed penalty

  13. Protection from falls of roof, face and ribs.

    violationRecord 5091984

    30 CFR 75.202(a) · Significant and substantial (S&S) · $4,383.00 proposed penalty

  14. Permanent splicing of trailing cables.

    violationRecord 5091983

    30 CFR 75.604(b) · $755.00 proposed penalty

  15. Permissible electric face equipment; maintenance.

    violationRecord 5091377

    30 CFR 75.503 · $209.00 proposed penalty

  16. Accumulation of combustible materials.

    violationRecord 5091376

    30 CFR 75.400 · $642.00 proposed penalty

  17. Permanent splicing of trailing cables.

    violationRecord 5091375

    30 CFR 75.604(b) · Significant and substantial (S&S) · $7,084.00 proposed penalty

  18. Inspection of fire suppression devices.

    violationRecord 5091374

    30 CFR 75.1107-16(b) · $209.00 proposed penalty

  19. Preshift examination at fixed intervals.

    violationRecord 9839649

    30 CFR 75.360(g) · $313.00 proposed penalty

  20. Electrical connections or splices; suitability.

    violationRecord 5091373

    30 CFR 75.514 · $1,037.00 proposed penalty

  21. Roof testing and scaling.

    violationRecord 5091372

    30 CFR 75.211(d) · $165.00 proposed penalty

  22. Electric equipment; examination, testing and maintenance.

    violationRecord 5091371

    30 CFR 75.512 · $336.00 proposed penalty

  23. Approval of other fire suppression devices.

    violationRecord 5091370

    30 CFR 75.1107-13(g) · $165.00 proposed penalty

  24. Methane monitors.

    violationRecord 5091369

    30 CFR 75.342(a)(4) · $209.00 proposed penalty

  25. Electric equipment; examination, testing and maintenance.

    violationRecord 5091368

    30 CFR 75.512 · $818.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.