PANTHER EAGLE MINE safety activity
MSHA violations, accident reports and inspections.
Safety activity
Maintenance of belt conveyors and belt conveyor entries.
30 CFR 75.1731(b) · $366.00 proposed penalty
Handtools (nonpowered)
Days away from work only
Accident narrative
Employee was working on the RCM replacing core breaker and wear shoes while putting the pin through the shoe and core breaker with a hammer something came off hitting their left eye.
Roof control plan.
30 CFR 75.220(a)(1) · $504.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · $697.00 proposed penalty
Automatic fire sensors and manual actuators; installation; minimum requirements.
30 CFR 75.1107-4(c) · $165.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · $398.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · $549.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $504.00 proposed penalty
Violation — cited standard not reported
$320.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · $549.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $3,736.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $1,968.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · $883.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $2,936.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $504.00 proposed penalty
Regular Safety and Health Inspection
363.0 on-site hours reported
Spot Inspection
6.0 on-site hours reported
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $642.00 proposed penalty
Disorders (repeated trauma)
Occupatnal illness not deg 1-6
Accident narrative
Employee was diagnosed with Carpal Tunnel Syndrome. Safety was notified on 12/19/2025.
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $313.00 proposed penalty
On-shift examination.
30 CFR 75.362(a)(2) · $959.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $1,431.00 proposed penalty
Inspection of fire suppression devices.
30 CFR 75.1107-16(b) · $151.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $432.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $432.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.