NO. 2 GAS safety activity
MSHA violations, accident reports and inspections.
Safety activity
Maintenance of belt conveyors and belt conveyor entries.
30 CFR 75.1731(b) · $151.00 proposed penalty
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S) · $1,818.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · Significant and substantial (S&S) · $2,312.00 proposed penalty
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $592.00 proposed penalty
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · $1,219.00 proposed penalty
Short circuit protection; ratings and settings of circuit breakers.
30 CFR 75.601-1 · $151.00 proposed penalty
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(7)(vii) · $3,184.00 proposed penalty
Roof bolting.
30 CFR 75.204(c)(1) · $245.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $2,712.00 proposed penalty
Other safeguards.
30 CFR 75.1403
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $549.00 proposed penalty
Emergency tethers.
30 CFR 75.1714-6 · $818.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $432.00 proposed penalty
Capacity of fire suppression devices; location and direction of nozzles.
30 CFR 75.1107-6(b) · $245.00 proposed penalty
Capacity of fire suppression devices; location and direction of nozzles.
30 CFR 75.1107-6(b) · $245.00 proposed penalty
Dry chemical devices; capacity; minimum requirements.
30 CFR 75.1107-9(a)(1) · $245.00 proposed penalty
Protection of trailing cables.
30 CFR 75.606 · $818.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $6,037.00 proposed penalty
Other safeguards.
30 CFR 75.1403
Quantity and location of firefighting equipment.
30 CFR 75.1100-2(f) · $245.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $1,550.00 proposed penalty
Automatic fire sensor and warning device systems; installation; minimum requirements.
30 CFR 75.1103-4(b) · $245.00 proposed penalty
Communications facilities; refuge alternatives.
30 CFR 75.1600-3(a)(2) · $245.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · $165.00 proposed penalty
Electrical connections or splices; suitability.
30 CFR 75.514 · $245.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.