← MINE NO. 1

MINE NO. 1 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Electric equipment; examination, testing and maintenance.

    violationRecord 9786966

    30 CFR 75.512 · Significant and substantial (S&S) · $1,037.00 proposed penalty

  2. Electric equipment; examination, testing and maintenance.

    violationRecord 9786965

    30 CFR 75.512 · $209.00 proposed penalty

  3. Accumulation of combustible materials.

    violationRecord 9786964

    30 CFR 75.400 · $313.00 proposed penalty

  4. Spot Inspections

    inspectionRecord 7023423

    103(i) · 6.5 on-site hours reported

  5. Spot Inspections

    inspectionRecord F007191

    103(i) · 6.5 on-site hours reported

  6. Accumulation of combustible materials.

    violationRecord 9549649

    30 CFR 75.400 · $313.00 proposed penalty

  7. Permanent splicing of trailing cables.

    violationRecord 9786963

    30 CFR 75.604(b) · $642.00 proposed penalty

  8. Accumulation of combustible materials.

    violationRecord 9789314

    30 CFR 75.400 · $313.00 proposed penalty

  9. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9789313

    30 CFR 75.1103-8(c) · $193.00 proposed penalty

  10. Nonpermissible diesel-powered equipment; design and performance requirements.

    violationRecord 9786962

    30 CFR 75.1909(a)(8) · $193.00 proposed penalty

  11. Maintenance of diesel-powered equipment.

    violationRecord 9786961

    30 CFR 75.1914(a) · Significant and substantial (S&S) · $1,037.00 proposed penalty

  12. Spot Inspections

    inspectionRecord 7023422

    103(i) · 14.3 on-site hours reported

  13. Protection from falls of roof, face and ribs.

    violationRecord 9786960

    30 CFR 75.202(a) · $226.00 proposed penalty

  14. Electric equipment; examination, testing and maintenance.

    violationRecord 9786959

    30 CFR 75.512 · $226.00 proposed penalty

  15. Warning devices.

    violationRecord 9786958

    30 CFR 75.208 · $642.00 proposed penalty

  16. Nonpermissible diesel-powered equipment; design and performance requirements.

    violationRecord 9786957

    30 CFR 75.1909(a)(2) · $193.00 proposed penalty

  17. Power wires and cables; insulation and protection.

    violationRecord 9786956

    30 CFR 75.517 · $697.00 proposed penalty

  18. Spot Inspections

    inspectionRecord F00223C

    103(i) · 4.0 on-site hours reported

  19. Spot Inspections

    inspectionRecord F00223B

    103(i) · 6.5 on-site hours reported

  20. Inspection of fire suppression devices.

    violationRecord 9786955

    30 CFR 75.1107-16(b) · $193.00 proposed penalty

  21. Shaft, Slope or Major Construction Spot Inspection

    inspectionRecord 7031350

    6.5 on-site hours reported

  22. Handling of materials

    accidentRecord 220252160022

    Days away from work only

    Accident narrative

    The crosshead for the Single Drum Lining Hoist became caught on top of a concrete pipe bracket that extended from the shaft liner 8.5" at 388' as the hook continued to be lowered down to a depth of 500'. The crew moved the work deck back to center the crosshead fell off the concrete pipe bracket and fell down to the headache ball causing 6' of damage to lower end of the hoist rope.

  23. Nonpermissible diesel-powered equipment; design and performance requirements.

    violationRecord 9786954

    30 CFR 75.1909(a)(3)(viii) · $193.00 proposed penalty

  24. Storage of liquefied and nonliquefied compressed gas cylinders; requirements.

    violationRecord 9786953

    30 CFR 75.1106-3(a)(2) · $193.00 proposed penalty

  25. Shaft, Slope or Major Construction Spot Inspection

    inspectionRecord 7031349

    4.5 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.