Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Spot Inspections
103(i) · 7.5 on-site hours reported
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S)
Permissible electric face equipment; maintenance.
30 CFR 75.503
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Regular Safety and Health Inspection
115.5 on-site hours reported
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Spot Inspections
103(i) · 6.5 on-site hours reported
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Ventilation controls.
30 CFR 75.333(h)
Self-rescue devices; use and location requirements.
30 CFR 75.1714-2(c)
Roof control plan.
30 CFR 75.220(a)(1) · Significant and substantial (S&S)
Spot Inspections
103(i) · 8.5 on-site hours reported
Air quality.
30 CFR 75.321(a)(1) · Significant and substantial (S&S)
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S)
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · Significant and substantial (S&S)
Spot Inspections
103(i) · 6.0 on-site hours reported
Fall of roof or back
Accident only
Accident narrative
A fall of roof occurred on the Main South belt at the #0 crosscut. The roof fall was approximately 18 feet in width by 9 feet in height by 22 feet in length. No personnel was injured during this event.
Non-Injury Accident Investigation
8.0 on-site hours reported
Violation — cited standard not reported
Accumulation of combustible materials.
30 CFR 75.400
Spot Inspections
103(i) · 7.0 on-site hours reported
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S)
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a)
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.