← EAGLE NO 1 MINE

EAGLE NO 1 MINE safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-28Database snapshot · 2026-10-28

Safety activity

  1. Fall of roof or back

    accidentRecord 220262860051

    Accident only

    Accident narrative

    An unplanned rooffall occurred on the south mains at break 69 and continued through to break 71 in the #6 entry. This is apprx 1000 feet from the 003/004 MMU. Fall Measure 20' Wide- 200' Long - 10' High. This fall does not affect ventilation or passage of persons, all approaches have been dangered off and the fall will not be rehabilitated at this time

  2. Non-Injury Accident Investigation

    inspectionRecord F02B539

    14.3 on-site hours reported

  3. Protection from falls of roof, face and ribs.

    violationRecord 5092579

    30 CFR 75.202(a) · Significant and substantial (S&S)

  4. Violation — cited standard not reported

    violationRecord 5092578
  5. Mine map.

    violationRecord 5131834

    30 CFR 75.1200 · $151.00 proposed penalty

  6. Mine ventilation plan; submission and approval.

    violationRecord 5131833

    30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $504.00 proposed penalty

  7. Identification of circuit breakers.

    violationRecord 5131832

    30 CFR 75.904 · $151.00 proposed penalty

  8. Installation of main mine fans.

    violationRecord 5131831

    30 CFR 75.310(a)(3) · $151.00 proposed penalty

  9. Verbal Hazard Complaint Inspections

    inspectionRecord F0307B6

    4.5 on-site hours reported

  10. Regular Safety and Health Inspection

    inspectionRecord F03DF76

    55.3 on-site hours reported

  11. Use of insulated cable handling equipment.

    violationRecord 5132530

    30 CFR 75.818(b) · $209.00 proposed penalty

  12. Cable fittings; suitability.

    violationRecord 5132529

    30 CFR 75.515 · $465.00 proposed penalty

  13. Low-, medium-, or high-voltage distribution circuits and equipment; repair.

    violationRecord 5132528

    30 CFR 75.511 · $465.00 proposed penalty

  14. Electric equipment; examination, testing and maintenance.

    violationRecord 5132527

    30 CFR 75.512 · $209.00 proposed penalty

  15. Testing, examination, and maintenance of circuit breakers; record.

    violationRecord 5132526

    30 CFR 75.900-4 · $151.00 proposed penalty

  16. Ventilation controls.

    violationRecord 5132525

    30 CFR 75.333(h) · $151.00 proposed penalty

  17. Regular Safety and Health Inspection

    inspectionRecord F025BD7

    47.0 on-site hours reported

  18. Electrical Technical Investigation

    inspectionRecord F00A107

    3.0 on-site hours reported

  19. Automatic couplers.

    violationRecord 5132508

    30 CFR 75.1405 · $151.00 proposed penalty

  20. Automatic fire sensor and warning device systems; installation; minimum requirements.

    violationRecord 5096097

    30 CFR 75.1103-4(a)(1)(i) · $313.00 proposed penalty

  21. Air quality detectors and measurement devices.

    violationRecord 5096096

    30 CFR 75.320(a) · $267.00 proposed penalty

  22. Changes in electric system map; recording.

    violationRecord 5096095

    30 CFR 75.508-2 · $165.00 proposed penalty

  23. Permanent splicing of trailing cables.

    violationRecord 5096094

    30 CFR 75.604(b) · Significant and substantial (S&S) · $4,383.00 proposed penalty

  24. Violation — cited standard not reported

    violationRecord 5096093

    $3,832.00 proposed penalty

  25. Approval of other fire suppression devices.

    violationRecord 5096092

    30 CFR 75.1107-13(g) · $151.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.