← Eagle Energy Mine No.1

Eagle Energy Mine No.1 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Electrical Technical Investigation

    inspectionRecord F006F0A

    3.0 on-site hours reported

  2. Machinery

    accidentRecord 220252730002

    No dys awy frm wrk,no rstr act

    Accident narrative

    Employee was installing roof support when finger was smashed between the drilling arm and the bolt head on the canopy post of the bolt machine.

  3. Spot Inspection

    inspectionRecord 6321996

    11.3 on-site hours reported

  4. Verbal Hazard Complaint Inspections

    inspectionRecord F015B50

    1.5 on-site hours reported

  5. Permissible electric face equipment; maintenance.

    violationRecord 5029905

    30 CFR 75.503 · $151.00 proposed penalty

  6. Power wires and cables; insulation and protection.

    violationRecord 5029904

    30 CFR 75.517 · $151.00 proposed penalty

  7. Permissible electric face equipment; maintenance.

    violationRecord 5029903

    30 CFR 75.503 · $151.00 proposed penalty

  8. Electric equipment; examination, testing and maintenance.

    violationRecord 5029902

    30 CFR 75.512 · Significant and substantial (S&S) · $245.00 proposed penalty

  9. Ventilation controls.

    violationRecord 5029901

    30 CFR 75.333(e)(1)(ii) · $151.00 proposed penalty

  10. Permissible electric face equipment; maintenance.

    violationRecord 5060800

    30 CFR 75.503 · $151.00 proposed penalty

  11. Drill dust control at underground areas of underground mines.

    violationRecord 5060799

    30 CFR 72.630(b) · $151.00 proposed penalty

  12. Permissible electric face equipment; maintenance.

    violationRecord 5060798

    30 CFR 75.503 · $151.00 proposed penalty

  13. Drill dust control at underground areas of underground mines.

    violationRecord 5060797

    30 CFR 72.630(b) · Significant and substantial (S&S) · $883.00 proposed penalty

  14. Water sprinkler systems; general.

    violationRecord 5060796

    30 CFR 75.1101-6 · $151.00 proposed penalty

  15. Roof control plan.

    violationRecord 9847571

    30 CFR 75.220(a)(1) · $165.00 proposed penalty

  16. Clamping of trailing cables to equipment.

    violationRecord 5060795

    30 CFR 75.605 · $151.00 proposed penalty

  17. Permanent splicing of trailing cables.

    violationRecord 5060794

    30 CFR 75.604(b) · Significant and substantial (S&S) · $549.00 proposed penalty

  18. Power wires and cables; insulation and protection.

    violationRecord 5060793

    30 CFR 75.517 · Significant and substantial (S&S) · $549.00 proposed penalty

  19. Power wires and cables; insulation and protection.

    violationRecord 5060792

    30 CFR 75.517 · Significant and substantial (S&S) · $1,818.00 proposed penalty

  20. Permissible electric face equipment; maintenance.

    violationRecord 5060790

    30 CFR 75.503 · $151.00 proposed penalty

  21. Power wires and cables; insulation and protection.

    violationRecord 5060789

    30 CFR 75.517 · Significant and substantial (S&S) · $549.00 proposed penalty

  22. Dry chemical devices; capacity; minimum requirements.

    violationRecord 5060788

    30 CFR 75.1107-9(a)(1) · $151.00 proposed penalty

  23. Permissible electric face equipment; maintenance.

    violationRecord 5060787

    30 CFR 75.503 · $151.00 proposed penalty

  24. Identification check system.

    violationRecord 5060786

    30 CFR 75.1715 · $151.00 proposed penalty

  25. Regular Safety and Health Inspection

    inspectionRecord F015B4E

    110.8 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.