Ventilation Technical Investigation
12.0 on-site hours reported
Violation — cited standard not reported
$480.00 proposed penalty
Powered haulage
No dys awy frm wrk,no rstr act
Accident narrative
While pulling a P pin from a belt drive with a scoop bucket pin turned striking EE's hand causing EE to lose tip of left pointer finger
Electrical Technical Investigation
14.0 on-site hours reported
Regular Safety and Health Inspection
149.5 on-site hours reported
Electric equipment; examination, testing, and maintenance.
30 CFR 77.502 · $2,312.00 proposed penalty
Cable fittings; suitability.
30 CFR 77.505 · $2,312.00 proposed penalty
Inspection of fire suppression devices.
30 CFR 75.1107-16(b) · $209.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $2,712.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $2,712.00 proposed penalty
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S) · $366.00 proposed penalty
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S) · $366.00 proposed penalty
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S) · $366.00 proposed penalty
Additional self-contained self-rescuers (SCSRs).
30 CFR 75.1714-4(b) · $151.00 proposed penalty
Travelways at surface installations.
30 CFR 77.205(e) · Significant and substantial (S&S) · $1,037.00 proposed penalty
Travelways at surface installations.
30 CFR 77.205(b) · $151.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty
Inspection of fire suppression devices.
30 CFR 75.1107-16(b) · $209.00 proposed penalty
Hazardous conditions and violations of mandatory health or safety standards; posting, correcting, and recording.
30 CFR 75.363(a) · $697.00 proposed penalty
Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.
30 CFR 75.1107-1(a)(3)(ii) · $151.00 proposed penalty
Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.
30 CFR 75.1107-1(a)(1) · $151.00 proposed penalty
Grounding offtrack direct-current machines and the enclosures of related detached components.
30 CFR 75.703 · $209.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $3,448.00 proposed penalty
Electrical Technical Investigation
13.5 on-site hours reported
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $398.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.