CARDINAL safety activity
MSHA violations, accident reports and inspections.
Safety activity
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $755.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $1,126.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $1,431.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $226.00 proposed penalty
Inspection of fire suppression devices.
30 CFR 75.1107-16(b) · $193.00 proposed penalty
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $226.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $226.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $1,431.00 proposed penalty
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty
Regular Safety and Health Inspection
1,132.8 on-site hours reported
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(7)(vii)(B) · $755.00 proposed penalty
Spot Inspections
103(i) · 12.8 on-site hours reported
Roof control plan.
30 CFR 75.220(a)(1) · $151.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $1,550.00 proposed penalty
Non-Injury Accident Investigation
7.5 on-site hours reported
Spot Inspection
21.0 on-site hours reported
Violation — cited standard not reported
Fall of roof or back
Accident only
Accident narrative
There was an unplanned roof fall at XC24 in the #5 entry in the 8th North Panel.
Fall of roof or back
Days away from work only
Accident narrative
Employee had set the ATRS and was in the process of starting to install the bolt near the rib, while on EE's left knee with EE's lower leg behind EE a piece of slate (1'8"W x 3'L x 1/2"T) contacted EE's lower left leg resulting in a fractured fibula.
Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers.
30 CFR 75.900 · $193.00 proposed penalty
Spot Inspections
103(i) · 6.0 on-site hours reported
Methane monitors.
30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · $313.00 proposed penalty
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $209.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.