← CARDINAL

CARDINAL safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Electric equipment; examination, testing and maintenance.

    violationRecord 5221119

    30 CFR 75.512 · $755.00 proposed penalty

  2. Permanent splicing of trailing cables.

    violationRecord 5221118

    30 CFR 75.604(b) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  3. Power wires and cables; insulation and protection.

    violationRecord 5221117

    30 CFR 75.517 · Significant and substantial (S&S) · $1,431.00 proposed penalty

  4. Electric equipment; examination, testing and maintenance.

    violationRecord 5221116

    30 CFR 75.512 · $226.00 proposed penalty

  5. Inspection of fire suppression devices.

    violationRecord 5221115

    30 CFR 75.1107-16(b) · $193.00 proposed penalty

  6. Methane monitors.

    violationRecord 5221114

    30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty

  7. Electric equipment; examination, testing and maintenance.

    violationRecord 5047714

    30 CFR 75.512 · $226.00 proposed penalty

  8. Electric equipment; examination, testing and maintenance.

    violationRecord 5047713

    30 CFR 75.512 · $226.00 proposed penalty

  9. Power wires and cables; insulation and protection.

    violationRecord 5046495

    30 CFR 75.517 · Significant and substantial (S&S) · $1,431.00 proposed penalty

  10. Methane monitors.

    violationRecord 5046494

    30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty

  11. Regular Safety and Health Inspection

    inspectionRecord F018BB7

    1,132.8 on-site hours reported

  12. Escapeways; bituminous and lignite mines.

    violationRecord 5221113

    30 CFR 75.380(d)(7)(vii)(B) · $755.00 proposed penalty

  13. Spot Inspections

    inspectionRecord F035D45

    103(i) · 12.8 on-site hours reported

  14. Roof control plan.

    violationRecord 5221112

    30 CFR 75.220(a)(1) · $151.00 proposed penalty

  15. Roof control plan.

    violationRecord 5221111

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $1,550.00 proposed penalty

  16. Non-Injury Accident Investigation

    inspectionRecord F022481

    7.5 on-site hours reported

  17. Spot Inspection

    inspectionRecord F020CCD

    21.0 on-site hours reported

  18. Violation — cited standard not reported

    violationRecord 9760813
  19. Fall of roof or back

    accidentRecord 220261890013

    Accident only

    Accident narrative

    There was an unplanned roof fall at XC24 in the #5 entry in the 8th North Panel.

  20. Fall of roof or back

    accidentRecord 220261950023

    Days away from work only

    Accident narrative

    Employee had set the ATRS and was in the process of starting to install the bolt near the rib, while on EE's left knee with EE's lower leg behind EE a piece of slate (1'8"W x 3'L x 1/2"T) contacted EE's lower left leg resulting in a fractured fibula.

  21. Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers.

    violationRecord 5047712

    30 CFR 75.900 · $193.00 proposed penalty

  22. Spot Inspections

    inspectionRecord F035D44

    103(i) · 6.0 on-site hours reported

  23. Methane monitors.

    violationRecord 5221108

    30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $642.00 proposed penalty

  24. Roof control plan.

    violationRecord 5221107

    30 CFR 75.220(a)(1) · $313.00 proposed penalty

  25. Permissible electric face equipment; maintenance.

    violationRecord 5045240

    30 CFR 75.503 · $209.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.