← BEAR BRANCH 2

BEAR BRANCH 2 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Permissible electric face equipment; maintenance.

    violationRecord 9779006

    30 CFR 75.503 · $245.00 proposed penalty

  2. Permissible electric face equipment; maintenance.

    violationRecord 9779005

    30 CFR 75.503

  3. Mobile equipment; automatic warning devices.

    violationRecord 9779041

    30 CFR 77.410(c) · $226.00 proposed penalty

  4. Accumulation of combustible materials.

    violationRecord 9779004

    30 CFR 75.400 · $465.00 proposed penalty

  5. Maintenance of diesel-powered equipment.

    violationRecord 9779003

    30 CFR 75.1914(a) · $226.00 proposed penalty

  6. Quantity and location of firefighting equipment.

    violationRecord 9779040

    30 CFR 75.1100-2(b) · $226.00 proposed penalty

  7. Permissible electric face equipment; maintenance.

    violationRecord 9779002

    30 CFR 75.503 · $407.00 proposed penalty

  8. Escapeways; bituminous and lignite mines.

    violationRecord 9779001

    30 CFR 75.380(d)(1) · $336.00 proposed penalty

  9. Escapeways; bituminous and lignite mines.

    violationRecord 9778689

    30 CFR 75.380(d)(1) · $336.00 proposed penalty

  10. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9778688

    30 CFR 75.1103-8(c) · $226.00 proposed penalty

  11. Accumulation of combustible materials.

    violationRecord 9778687

    30 CFR 75.400 · $465.00 proposed penalty

  12. Automatic fire warning devices; actions and response.

    violationRecord 9774114

    30 CFR 75.1103-5(a)(1) · $226.00 proposed penalty

  13. Permanent splicing of trailing cables.

    violationRecord 9774113

    30 CFR 75.604(c) · $226.00 proposed penalty

  14. Electric equipment; examination, testing and maintenance.

    violationRecord 9774112

    30 CFR 75.512 · $336.00 proposed penalty

  15. Spot Inspections

    inspectionRecord F000F8A

    103(i) · 7.0 on-site hours reported

  16. Electric equipment; examination, testing and maintenance.

    violationRecord 9779000

    30 CFR 75.512 · $151.00 proposed penalty

  17. Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.

    violationRecord 9778999

    30 CFR 75.1600-2 · $151.00 proposed penalty

  18. Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.

    violationRecord 9778998

    30 CFR 75.1600-2 · $151.00 proposed penalty

  19. Installation of main mine fans.

    violationRecord 9774111

    30 CFR 75.310(a)(3) · $226.00 proposed penalty

  20. Electric equipment; examination, testing and maintenance.

    violationRecord 9778997

    30 CFR 75.512 · $336.00 proposed penalty

  21. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9778686

    30 CFR 75.1103-8(c) · $226.00 proposed penalty

  22. Preshift examination at fixed intervals.

    violationRecord 9778996

    30 CFR 75.360(g) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  23. Protection from falls of roof, face and ribs.

    violationRecord 9778995

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  24. Mine ventilation plan; submission and approval.

    violationRecord 9778994

    30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $2,712.00 proposed penalty

  25. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9774110

    30 CFR 75.1103-8(c) · $226.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.