# 2 safety activity
MSHA violations, accident reports and inspections.
Safety activity
Grounding metallic frames, casings, and other enclosures of electric equipment.
30 CFR 75.701 · Significant and substantial (S&S) · $209.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $209.00 proposed penalty
Regular Safety and Health Inspection
145.8 on-site hours reported
Fall of roof or back
Accident only
Accident narrative
There was a Non-Injury Roof Fall that occurred at this mine on 09/22/2025 in the #4 Belt Entry at Spad #93 on the South Mains
Non-Injury Accident Investigation
65.0 on-site hours reported
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $151.00 proposed penalty
Violation — cited standard not reported
Roof testing and scaling.
30 CFR 75.211(d) · $151.00 proposed penalty
Regular Safety and Health Inspection
38.3 on-site hours reported
Fall of roof or back
Accident only
Accident narrative
There was a Non-Injury Roof Fall which occurred at this mine 0n 06/24/2026. No employees were there when the Roof Fall occurred.
Roof control plan.
30 CFR 75.220(a)(1) · $151.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · $151.00 proposed penalty
Methane monitors.
30 CFR 75.342(a)(4) · $151.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $245.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $165.00 proposed penalty
Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives.
30 CFR 75.1101 · $151.00 proposed penalty
Accumulations of combustible materials.
30 CFR 77.1104 · $151.00 proposed penalty
First-aid equipment; location; minimum requirements.
30 CFR 75.1713-7(a)(1) · $151.00 proposed penalty
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $151.00 proposed penalty
Cable fittings; suitability.
30 CFR 75.515 · $151.00 proposed penalty
Permanent splicing of trailing cables.
30 CFR 75.604(b) · Significant and substantial (S&S) · $245.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · $151.00 proposed penalty
Regular Safety and Health Inspection
176.5 on-site hours reported
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $398.00 proposed penalty
Spot Inspection
30.5 on-site hours reported
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.