  1. Spot Inspections

    inspectionRecord F00EBE5
    Laurel Fork Mine · 4609084

    103(i) · 5.5 on-site hours reported

  2. Storage of liquefied and nonliquefied compressed gas cylinders; requirements.

    violationRecord 5093136
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.1106-3(c) · $151.00 proposed penalty

  3. Power wires and cables; insulation and protection.

    violationRecord 5093135
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.517 · Significant and substantial (S&S) · $3,448.00 proposed penalty

  4. Protection from falls of roof, face and ribs.

    violationRecord 9879070
    Berwind Deep Mine · 4609533

    30 CFR 75.202(a) · Significant and substantial (S&S) · $4,749.00 proposed penalty

  5. Protection from falls of roof, face and ribs.

    violationRecord 9879069
    Berwind Deep Mine · 4609533

    30 CFR 75.202(a) · Significant and substantial (S&S) · $4,749.00 proposed penalty

  6. Other safeguards.

    violationRecord 9879068
    Berwind Deep Mine · 4609533

    30 CFR 75.1403 · $313.00 proposed penalty

  7. Roof control plan.

    violationRecord 9878934
    Berwind Deep Mine · 4609533

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $3,184.00 proposed penalty

  8. Protection from falls of roof, face and ribs.

    violationRecord 9878933
    Berwind Deep Mine · 4609533

    30 CFR 75.202(a) · Significant and substantial (S&S) · $3,184.00 proposed penalty

  9. Accumulation of combustible materials.

    violationRecord 9878932
    Berwind Deep Mine · 4609533

    30 CFR 75.400 · $642.00 proposed penalty

  10. Grounding metallic sheaths, armors, and conduits enclosing power conductors.

    violationRecord 9837196
    NO. 2 GAS · 4609541

    30 CFR 75.700 · $226.00 proposed penalty

  11. Quantity and location of firefighting equipment.

    violationRecord 5131711
    NO. 2 GAS · 4609541

    30 CFR 75.1100-2(f) · $151.00 proposed penalty

  12. Short circuit protection; ratings and settings of circuit breakers.

    violationRecord 5131018
    NO. 2 GAS · 4609541

    30 CFR 75.601-1 · $336.00 proposed penalty

  13. Handling of materials

    accidentRecord 220253560008
    Berwind Deep Mine · 4609533

    Days away from work only

    Accident narrative

    EE was lifting a timber and felt a pain in EE's groin area

  14. Roof control plan.

    violationRecord 5093134
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.220(a)(1) · $549.00 proposed penalty

  15. Electric equipment; examination, testing and maintenance.

    violationRecord 5093133
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.512 · $2,936.00 proposed penalty

  16. Permissible electric face equipment; maintenance.

    violationRecord 5093132
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.503 · $226.00 proposed penalty

  17. Power wires and cables; insulation and protection.

    violationRecord 5093131
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.517 · Significant and substantial (S&S) · $3,448.00 proposed penalty

  18. Machinery and equipment; operation and maintenance.

    violationRecord 5131710
    NO. 2 GAS · 4609541

    30 CFR 75.1725(a) · $226.00 proposed penalty

  19. Other safeguards.

    violationRecord 5131709
    NO. 2 GAS · 4609541

    30 CFR 75.1403 · $226.00 proposed penalty

  20. Spot Inspections

    inspectionRecord 4411875
    Berwind Deep Mine · 4609533

    103(i) · 6.0 on-site hours reported

  21. Verbal Hazard Complaint Inspections

    inspectionRecord F00EAF2
    Elk Creek Plant · 4602444

    13.5 on-site hours reported

  22. Electric equipment; examination, testing and maintenance.

    violationRecord 5093130
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.512 · $177.00 proposed penalty

  23. Ventilation controls.

    violationRecord 5093129
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.333(c)(1) · $151.00 proposed penalty

  24. Preshift examination at fixed intervals.

    violationRecord 5093128
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.360(f) · $151.00 proposed penalty

  25. Electric equipment; examination, testing and maintenance.

    violationRecord 5093127
    Stonecoal Branch Mine No. 2 · 4608663

    30 CFR 75.512 · Significant and substantial (S&S) · $9,757.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.