MSHA violations, accident reports and inspections across the current mine portfolio.
Safety activity
Electrical conductors.
Odessa Cement Plant · 410006030 CFR 56.12004 · $151.00 proposed penalty
Written safety program.
Nemo Plant · 410506830 CFR 56.23002(b) · $151.00 proposed penalty
Warning signs.
Nemo Plant · 410506830 CFR 56.4101 · $151.00 proposed penalty
Requirement for container labels.
Nemo Plant · 410506830 CFR 47.41(a) · $151.00 proposed penalty
Horns and backup alarms.
Nemo Plant · 410506830 CFR 56.14132(a) · Significant and substantial (S&S) · $177.00 proposed penalty
Regular Safety and Health Inspection
Odessa Cement Plant · 4100060113.0 on-site hours reported
Regular Safety and Health Inspection
Nemo Plant · 410506813.0 on-site hours reported
Automatic fire sensor and warning device systems; installation; minimum requirements.
King II · 050486430 CFR 75.1103-4(b) · $151.00 proposed penalty
Parking procedures for unattended equipment.
Nemo Plant · 410506830 CFR 56.14207 · $151.00 proposed penalty
Parking procedures for unattended equipment.
Nemo Plant · 410506830 CFR 56.14207 · $151.00 proposed penalty
Parking procedures for unattended equipment.
Nemo Plant · 410506830 CFR 56.14207 · $151.00 proposed penalty
Requirement for container labels.
Nemo Plant · 410506830 CFR 47.41(a) · $151.00 proposed penalty
Life jackets and belts.
Nemo Plant · 410506830 CFR 56.15020 · Significant and substantial (S&S) · $177.00 proposed penalty
Stepping or kneeling on object
Odessa Cement Plant · 4100060Dys awy frm wrk & restrctd act
Accident narrative
Employee was fueling front end loader and walked away from the equipment and when EE heard the fuel overflowing ran to stop it, stepped on a rock and employee sprained the ankle.
Handling of materials
Pueblo Plant & Quarry · 0504822Days restricted activity only
Accident narrative
Miner was shoveling rock into buckets at the tail end of the limestone tunnel and hauling the buckets outside the tunnel to dump. Miner hurt their lower back in the process.
Electrical connections or splices; suitability.
King II · 050486430 CFR 75.514 · $151.00 proposed penalty
Handling of materials
GCC Dacotah Inc · 3900022Days restricted activity only
Accident narrative
The employee was assisting in installing a new drop pipe. The pipe remained secured but shifted from its placement, and the employee on the ground had a hold of it to keep it from swinging and felt the impact of the pipe shifting and felt discomfort in EE's back.
Mine ventilation plan; submission and approval.
King II · 050486430 CFR 75.370(a)(1) · Significant and substantial (S&S) · $6,037.00 proposed penalty
Permissible electric face equipment; maintenance.
King II · 050486430 CFR 75.503 · $151.00 proposed penalty
Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.
King II · 050486430 CFR 75.1600-2(e) · $151.00 proposed penalty
Nonpermissible diesel-powered equipment; design and performance requirements.
King II · 050486430 CFR 75.1909(b)(2) · $151.00 proposed penalty
Permanent splicing of trailing cables.
King II · 050486430 CFR 75.604(b) · $151.00 proposed penalty
Condition and examination of firefighting equipment.
King II · 050486430 CFR 75.1100-3 · $151.00 proposed penalty
Nonpermissible diesel-powered equipment; design and performance requirements.
King II · 050486430 CFR 75.1909(d) · $209.00 proposed penalty
Power wires and cables; insulation and protection.
King II · 050486430 CFR 75.517 · $151.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.