← St. Marys Cement U.S. LLC

St. Marys Cement U.S. LLC safety activity

MSHA violations, accident reports and inspections across the current mine portfolio.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Insulation and fittings for power wires and cables.

    violationRecord 5110003
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12008 · $151.00 proposed penalty

  2. Housekeeping.

    violationRecord 5110002
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.20003(a) · Significant and substantial (S&S) · $1,037.00 proposed penalty

  3. Berms or guardrails.

    violationRecord 6553488
    St Marys Cement-Detroit · 2002434

    30 CFR 56.9300(a) · $151.00 proposed penalty

  4. Construction and maintenance of guards.

    violationRecord 6553487
    St Marys Cement-Detroit · 2002434

    30 CFR 56.14112(b) · $209.00 proposed penalty

  5. Electrical conductors.

    violationRecord 8672400
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12004 · $151.00 proposed penalty

  6. Protective equipment or clothing for welding, cutting, or working with molten metal.

    violationRecord 8672399
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.15007 · Significant and substantial (S&S) · $313.00 proposed penalty

  7. Testing grounding systems.

    violationRecord 6184893
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12028 · $151.00 proposed penalty

  8. Grounding circuit enclosures.

    violationRecord 6184892
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12025 · $313.00 proposed penalty

  9. Housekeeping.

    violationRecord 6184890
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.20003(a) · $755.00 proposed penalty

  10. Testing grounding systems.

    violationRecord 6184889
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12028 · $151.00 proposed penalty

  11. Housekeeping.

    violationRecord 5110001
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.20003(a) · $226.00 proposed penalty

  12. Construction and maintenance of guards.

    violationRecord 6553486
    St Marys Cement-Detroit · 2002434

    30 CFR 56.14112(b) · $209.00 proposed penalty

  13. Housekeeping.

    violationRecord 6553485
    St Marys Cement-Detroit · 2002434

    30 CFR 56.20003(a) · $592.00 proposed penalty

  14. Compliance Follow-up Inspection

    inspectionRecord F01483F
    St. Marys Cement-Charlevoix · 2000038

    10.5 on-site hours reported

  15. Regular Safety and Health Inspection

    inspectionRecord F0079B8
    St. Marys Cement-Charlevoix · 2000038

    215.8 on-site hours reported

  16. Housekeeping.

    violationRecord 8672398
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.20003(a) · $226.00 proposed penalty

  17. Combustible waste.

    violationRecord 8672397
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.4104(b) · $151.00 proposed penalty

  18. Protection of gas cylinder valves.

    violationRecord 8672396
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.16006 · $151.00 proposed penalty

  19. General requirements.

    violationRecord 8672395
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.4200(b)(2) · $151.00 proposed penalty

  20. Grounding circuit enclosures.

    violationRecord 6184888
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.12025 · $313.00 proposed penalty

  21. Extinguisher recharging or replacement.

    violationRecord 6184887
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.4203 · $151.00 proposed penalty

  22. Gauges and regulators.

    violationRecord 6184886
    St. Marys Cement-Charlevoix · 2000038

    30 CFR 56.4602 · $151.00 proposed penalty

  23. Grounding circuit enclosures.

    violationRecord 6553484
    St Marys Cement-Detroit · 2002434

    30 CFR 56.12025 · $151.00 proposed penalty

  24. Eye protection when operating grinding wheels.

    violationRecord 6553483
    St Marys Cement-Detroit · 2002434

    30 CFR 56.15014 · Significant and substantial (S&S) · $818.00 proposed penalty

  25. Housekeeping.

    violationRecord 6553482
    St Marys Cement-Detroit · 2002434

    30 CFR 56.20003(a) · $1,431.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.