Southwest Critical Materials LLC safety activity
MSHA violations, accident reports and inspections across the current mine portfolio.
Safety activity
Hoisting
Pumpkin Hollow East Underground · 2602711Accident only
Accident narrative
Breakers for the Hoist House tripped due to electrical storm activity. Main line power to the hoisting conveyance was disrupted until the breakers could be reset. The breakers were reset and power was restored to the hoisting conveyance.
Safety defects; examination, correction and records.
Pumpkin Hollow East Underground · 260271130 CFR 57.14100(c) · Significant and substantial (S&S) · $151.00 proposed penalty
Hoisting
Pumpkin Hollow East Underground · 2602711Accident only
Accident narrative
While performing pre shift hoisting conveyance checks, the lower limit switch showed a fault causing the checks to fail that part of the testing. The lower limit switch was stuck due to small buildup of concrete on it. The limit switch was cleaned allowing the checks to pass.
Handling of materials
Pumpkin Hollow East Underground · 2602711Days restricted activity only
Accident narrative
During innertube retrieval, side loading occurred while the helper attempted to free the stuffing box by pushing/pulling on it. When released, the stuffing box deflected slightly outside the perceived red zone and the 90� pump-down hose contacted the helper's right ankle, causing a fall and ankle sprain.
Regular Safety and Health Inspection
Pumpkin Hollow East Underground · 260271137.5 on-site hours reported
Hoisting
Pumpkin Hollow East Underground · 2602711Accident only
Accident narrative
Auxiliary Cage in the main shaft conveyance taken out of automated use for unscheduled improvement/upgrades to provide corrective actions for a HP Near Miss incident. No injuries, damage to equipment, or entrapment were encountered. The work will focus on upgrades to the automation programming and interlocks.
Hoisting
Pumpkin Hollow East Underground · 2602711Accident only
Accident narrative
Damage received to aluminum rail of the service cage as the cage was shipped underground to transport materials. Downtime occurred due to repairs needed on the aluminum rail.
Verbal Hazard Complaint Inspections
Pumpkin Hollow East Underground · 26027113.0 on-site hours reported
Handling of materials
Pumpkin Hollow East Underground · 2602711Days restricted activity only
Accident narrative
After pulling the inner tube with the latch head, the helper walked to the tube rack. While placing the tube, weight shifted toward the latch head, causing EE to lose balance slightly. EE's right hand lowered, and EE's ring finger was caught under the latch head as it contacted the rack. EE was wearing impact gloves.
Verbal Hazard Complaint Inspections
Pumpkin Hollow East Underground · 26027119.0 on-site hours reported
Hoisting
Pumpkin Hollow East Underground · 2602711Accident only
Accident narrative
Service Cage Damage. Upper brattice door was damaged while transporting materials down the shaft causing the brattice doors to interfere with the use of the cage. The brattice doors were repaired and the cage was put back into operation later that day.
Barricades and warning signs.
Pumpkin Hollow East Underground · 260271130 CFR 57.20011 · $151.00 proposed penalty
Electrical conductors.
Pumpkin Hollow East Underground · 260271130 CFR 57.12004 · $151.00 proposed penalty
Verbal Hazard Complaint Inspections
Pumpkin Hollow East Underground · 26027118.0 on-site hours reported
Regular Safety and Health Inspection
Pumpkin Hollow East Underground · 260271112.0 on-site hours reported
Verbal Hazard Complaint Inspections
Pumpkin Hollow East Underground · 260271117.5 on-site hours reported
Compliance Follow-up Inspection
Pumpkin Hollow East Underground · 26027113.5 on-site hours reported
Equipment and maintenance requirements.
Pumpkin Hollow East Underground · 260271130 CFR 49.6(a)(5) · $151.00 proposed penalty
Storage of flammable liquids underground.
Pumpkin Hollow East Underground · 260271130 CFR 57.4460(a)(1) · $151.00 proposed penalty
Correction of dangerous conditions.
Pumpkin Hollow East Underground · 260271130 CFR 57.12030 · $151.00 proposed penalty
Requirement for container labels.
Pumpkin Hollow East Underground · 260271130 CFR 47.41(a) · $151.00 proposed penalty
Inspection and cover plates.
Pumpkin Hollow East Underground · 260271130 CFR 57.12032 · $151.00 proposed penalty
Moving machine parts.
Pumpkin Hollow East Underground · 260271130 CFR 57.14107(a) · $151.00 proposed penalty
Ground support use.
Pumpkin Hollow East Underground · 260271130 CFR 57.3360 · $151.00 proposed penalty
Ladderway trap doors and guards.
Pumpkin Hollow East Underground · 260271130 CFR 57.11036 · Significant and substantial (S&S) · $697.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.