River Cement Company dba Buzzi Unicem USA safety activity
MSHA violations, accident reports and inspections across the current mine portfolio.
Safety activity
Illumination of surface working areas.
Selma Plant Quarry & Mill · 230018830 CFR 56.17001
Illumination of surface working areas.
Selma Plant Quarry & Mill · 230018830 CFR 56.17001
Illumination of surface working areas.
Selma Plant Quarry & Mill · 230018830 CFR 56.17001
Correction of dangerous conditions.
Selma Plant Quarry & Mill · 230018830 CFR 56.12030
Control of exposure to airborne contaminants.
Selma Plant Quarry & Mill · 230018830 CFR 56.5005(a) · Significant and substantial (S&S)
Correction of dangerous conditions.
Selma Plant Quarry & Mill · 230018830 CFR 56.12030
Housekeeping.
Selma Plant Quarry & Mill · 230018830 CFR 56.20003(b) · Significant and substantial (S&S)
Correction of dangerous conditions.
Selma Plant Quarry & Mill · 230018830 CFR 56.12030
Air receiver tanks.
Selma Plant Quarry & Mill · 230018830 CFR 56.13011
Air receiver tanks.
Selma Plant Quarry & Mill · 230018830 CFR 56.13011
Inspection.
Selma Plant Quarry & Mill · 230018830 CFR 56.4201(a)(1)
Safety defects; examination, correction and records.
Selma Plant Quarry & Mill · 230018830 CFR 56.14100(b)
Requirement for container labels.
Selma Plant Quarry & Mill · 230018830 CFR 47.41(a)
Danger signs.
Selma Plant Quarry & Mill · 230018830 CFR 56.12021
Electric substations and liquid storage facilities.
Selma Plant Quarry & Mill · 230018830 CFR 56.4130(b)
Air receiver tanks.
Selma Plant Quarry & Mill · 230018830 CFR 56.13011
Illumination of surface working areas.
Selma Plant Quarry & Mill · 230018830 CFR 56.17001
Identification of power switches.
Selma Plant Quarry & Mill · 230018830 CFR 56.12018
Housekeeping.
Selma Plant Quarry & Mill · 230018830 CFR 56.20003(a) · Significant and substantial (S&S)
Horns and backup alarms.
Selma Plant Quarry & Mill · 230018830 CFR 56.14132(a)
Regular Safety and Health Inspection
Selma Plant Quarry & Mill · 230018844.0 on-site hours reported
Berms or guardrails.
Selma Plant Quarry & Mill · 230018830 CFR 56.9300(a) · Significant and substantial (S&S)
Machinery
Selma Plant Quarry & Mill · 2300188Days away from work only
Accident narrative
EE on Preheat Tower found a water gun disconnected from its hose with the water valve closed. A miner asked on the radio if the "pressure was good" and they heard someone say "yes". When EE began to screw the hose coupling onto the gun, the other miner opened the water valve. High pressure water then shot out of the coupling and was injected with a piece of cloth into EE's hand.
Other
Selma Plant Quarry & Mill · 2300188Days away from work only
Accident narrative
EE complained of slight dizziness throughout the evening. A little later EE fainted and their partner immediately called the Control Room to report this, and when they turned around EE had already regained consciousness.
Impoundment Spot Inspection
Selma Plant Quarry & Mill · 23001886.0 on-site hours reported
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.