← Knight Hawk Coal LLC

Knight Hawk Coal LLC safety activity

MSHA violations, accident reports and inspections across the current mine portfolio.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Electric equipment; examination, testing and maintenance.

    violationRecord 9789614
    Prairie Eagle-Underground · 1103147

    30 CFR 75.512 · $1,219.00 proposed penalty

  2. Roof control plan.

    violationRecord 9789613
    Prairie Eagle-Underground · 1103147

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $20,047.00 proposed penalty

  3. Protection from falls of roof, face and ribs.

    violationRecord 9789612
    Prairie Eagle-Underground · 1103147

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  4. Protection from falls of roof, face and ribs.

    violationRecord 9789611
    Prairie Eagle-Underground · 1103147

    30 CFR 75.202(a) · Significant and substantial (S&S) · $18,504.00 proposed penalty

  5. Maintenance of diesel-powered equipment.

    violationRecord 5011623
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1914(a) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  6. Spot Inspections

    inspectionRecord 7031399
    Prairie Eagle-Underground · 1103147

    103(i) · 5.3 on-site hours reported

  7. Fire suppression systems for diesel-powered equipment and fuel transportation units.

    violationRecord 9789610
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1911(d) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  8. Ventilation controls.

    violationRecord 5011622
    Prairie Eagle-Underground · 1103147

    30 CFR 75.333(h) · $245.00 proposed penalty

  9. Handling of materials

    accidentRecord 220252260018
    Prairie Eagle-Underground · 1103147

    Days away from work only

    Accident narrative

    I.E. was lifting rub rail on continuous miner to put back into place. As the I.E. raised the bar they felt a pop in their left elbow. I.E. continued to work until doctor's restrictions took them off work on 8/7/2025.

  10. Non-Injury Accident Investigation

    inspectionRecord 7031398
    Prairie Eagle-Underground · 1103147

    5.8 on-site hours reported

  11. Violation — cited standard not reported

    violationRecord 9789609
    Prairie Eagle-Underground · 1103147
  12. Fall of roof or back

    accidentRecord 220252270013
    Prairie Eagle-Underground · 1103147

    Accident only

    Accident narrative

    A roof fall occurred at this location on 8-5-2025. The fall location was on the 2nd East in entry #5 in the intersection at survey station 12+00. The fall measured 20ft wide, 40 ft long, and 6-7ft high. No one was injured.

  13. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9789608
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1731(b) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  14. Protection from falls of roof, face and ribs.

    violationRecord 9789607
    Prairie Eagle-Underground · 1103147

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  15. Protection from falls of roof, face and ribs.

    violationRecord 5011618
    Prairie Eagle-Underground · 1103147

    30 CFR 75.202(a) · $336.00 proposed penalty

  16. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9549646
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1731(a) · $245.00 proposed penalty

  17. Protection from falls of roof, face and ribs.

    violationRecord 9549645
    Prairie Eagle-Underground · 1103147

    30 CFR 75.202(a) · $1,126.00 proposed penalty

  18. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9789311
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1103-8(c) · $267.00 proposed penalty

  19. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9789310
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1103-8(c) · $267.00 proposed penalty

  20. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 9789309
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1103-8(c) · $267.00 proposed penalty

  21. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9789308
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1731(b) · $226.00 proposed penalty

  22. Other safeguards.

    violationRecord 9789307
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1403 · $226.00 proposed penalty

  23. Spot Inspections

    inspectionRecord 7031397
    Prairie Eagle-Underground · 1103147

    103(i) · 6.5 on-site hours reported

  24. Methane monitors.

    violationRecord 9789606
    Prairie Eagle-Underground · 1103147

    30 CFR 75.342(a)(4) · $177.00 proposed penalty

  25. Machinery and equipment; operation and maintenance.

    violationRecord 9789605
    Prairie Eagle-Underground · 1103147

    30 CFR 75.1725(a) · Significant and substantial (S&S) · $1,219.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.