← Consol Pennsylvania Coal Company LLC

Consol Pennsylvania Coal Company LLC safety activity

MSHA violations, accident reports and inspections across the current mine portfolio.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Spot Inspections

    inspectionRecord F02F23D
    Bailey Mine · 3607230

    103(i) · 5.0 on-site hours reported

  2. Spot Inspections

    inspectionRecord F00701A
    HARVEY MINE · 3610045

    103(i) · 6.5 on-site hours reported

  3. Roof control plan.

    violationRecord 9935605
    Bailey Mine · 3607230

    30 CFR 75.220(a)(1) · $226.00 proposed penalty

  4. Power wires and cables; insulation and protection.

    violationRecord 9935604
    Bailey Mine · 3607230

    30 CFR 75.517 · $288.00 proposed penalty

  5. Accumulation of combustible materials.

    violationRecord 9935603
    Bailey Mine · 3607230

    30 CFR 75.400 · $165.00 proposed penalty

  6. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9824644
    Bailey Mine · 3607230

    30 CFR 75.1731(b) · $151.00 proposed penalty

  7. Refuge alternatives.

    violationRecord 9605604
    HARVEY MINE · 3610045

    30 CFR 75.1506(g) · $151.00 proposed penalty

  8. Other safeguards.

    violationRecord 9605600
    HARVEY MINE · 3610045

    30 CFR 75.1403 · $151.00 proposed penalty

  9. Accumulation of combustible materials.

    violationRecord 5151476
    HARVEY MINE · 3610045

    30 CFR 75.400 · $151.00 proposed penalty

  10. Ventilation controls.

    violationRecord 5151475
    HARVEY MINE · 3610045

    30 CFR 75.333(h) · $151.00 proposed penalty

  11. Spot Inspections

    inspectionRecord F014D64
    ENLOW FORK MINE · 3607416

    103(i) · 4.5 on-site hours reported

  12. Ventilation Technical Investigation

    inspectionRecord F017D75
    HARVEY MINE · 3610045

    54.5 on-site hours reported

  13. Roof control plan.

    violationRecord 9935566
    Bailey Mine · 3607230

    30 CFR 75.220(a)(1) · $226.00 proposed penalty

  14. Short circuit protection; ratings and settings of circuit breakers.

    violationRecord 5156235
    ENLOW FORK MINE · 3607416

    30 CFR 75.601-1 · $165.00 proposed penalty

  15. Machinery and equipment; operation and maintenance.

    violationRecord 5156234
    ENLOW FORK MINE · 3607416

    30 CFR 75.1725(a) · $151.00 proposed penalty

  16. Machinery and equipment; operation and maintenance.

    violationRecord 5151816
    ENLOW FORK MINE · 3607416

    30 CFR 75.1725(a) · $165.00 proposed penalty

  17. High-voltage underground equipment; grounding.

    violationRecord 7118099
    HARVEY MINE · 3610045

    30 CFR 75.811 · $549.00 proposed penalty

  18. Fire suppression systems for diesel-powered equipment and fuel transportation units.

    violationRecord 5156693
    HARVEY MINE · 3610045

    30 CFR 75.1911(i) · $151.00 proposed penalty

  19. Conventional roof support.

    violationRecord 5156692
    HARVEY MINE · 3610045

    30 CFR 75.206(e) · $151.00 proposed penalty

  20. Protection from falls of roof, face and ribs.

    violationRecord 5156691
    HARVEY MINE · 3610045

    30 CFR 75.202(a) · $151.00 proposed penalty

  21. Fall of roof or back

    accidentRecord 220261340023
    Bailey Mine · 3607230

    No dys awy frm wrk,no rstr act

    Accident narrative

    Employee was side bolting when a rock fell from above the rib protector striking EE causing lacerations. EE was treated with sutures to close the lacerations. EE was released to work EE's next scheduled shift.

  22. Verbal Hazard Complaint Inspections

    inspectionRecord F01536B
    Bailey Mine · 3607230

    14.0 on-site hours reported

  23. Roof Control Technical Investigation

    inspectionRecord F016759
    ENLOW FORK MINE · 3607416

    38.0 on-site hours reported

  24. Health Technical Investigation

    inspectionRecord F00F03B
    HARVEY MINE · 3610045

    11.0 on-site hours reported

  25. Accumulation of combustible materials.

    violationRecord 9824643
    Bailey Mine · 3607230

    30 CFR 75.400 · $165.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.