  1. Preshift examination at fixed intervals.

    violationRecord 5020358

    30 CFR 75.360(g) · $151.00 proposed penalty

  2. Roof control plan.

    violationRecord 5020357

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $1,219.00 proposed penalty

  3. Accumulation of combustible materials.

    violationRecord 5020356

    30 CFR 75.400 · $165.00 proposed penalty

  4. Electric equipment; examination, testing and maintenance.

    violationRecord 5020355

    30 CFR 75.512 · $165.00 proposed penalty

  5. Air quality.

    violationRecord 5020354

    30 CFR 75.321(a)(1) · $165.00 proposed penalty

  6. Ventilation controls.

    violationRecord 5020353

    30 CFR 75.333(h) · $165.00 proposed penalty

  7. Roof bolting.

    violationRecord 5020352

    30 CFR 75.204(f)(7) · $165.00 proposed penalty

  8. Electric equipment; examination, testing and maintenance.

    violationRecord 5020351

    30 CFR 75.512 · $165.00 proposed penalty

  9. Roof control plan.

    violationRecord 5020349

    30 CFR 75.220(a)(1) · $165.00 proposed penalty

  10. Accumulation of combustible materials.

    violationRecord 5020346

    30 CFR 75.400 · $165.00 proposed penalty

  11. Installation of high-voltage transmission cables.

    violationRecord 5020345

    30 CFR 75.807 · $165.00 proposed penalty

  12. Regular Safety and Health Inspection

    inspectionRecord 6322994

    162.8 on-site hours reported

  13. Mine ventilation plan; submission and approval.

    violationRecord 5020343

    30 CFR 75.370(d) · $366.00 proposed penalty

  14. Storage of liquefied and nonliquefied compressed gas cylinders; requirements.

    violationRecord 5020342

    30 CFR 75.1106-3(a)(2) · $165.00 proposed penalty

  15. Roof control plan.

    violationRecord 5020341

    30 CFR 75.220(a)(1) · $165.00 proposed penalty

  16. Roof bolting.

    violationRecord 5020339

    30 CFR 75.204(f)(4) · $165.00 proposed penalty

  17. Permissible electric face equipment; maintenance.

    violationRecord 5025124

    30 CFR 75.503 · $592.00 proposed penalty

  18. Methane monitors.

    violationRecord 5020338

    30 CFR 75.342(a)(4) · $165.00 proposed penalty

  19. Condition and examination of firefighting equipment.

    violationRecord 5020337

    30 CFR 75.1100-3 · $151.00 proposed penalty

  20. Automatic fire sensors and manual actuators; installation; minimum requirements.

    violationRecord 5020336

    30 CFR 75.1107-4(c) · $165.00 proposed penalty

  21. Automatic fire warning devices; actions and response.

    violationRecord 5020335

    30 CFR 75.1103-5(d) · $165.00 proposed penalty

  22. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 5020334

    30 CFR 75.1103-8(c) · $151.00 proposed penalty

  23. Fall of roof or back

    accidentRecord 220251070016

    Accident only

    Accident narrative

    An unplanned roof fall occurred on 4/16/2025 at approximately 10:30 am on the 1 section, which is currently retreat mining in front of an MRS in the No. 3 Entry at 16 crosscut on the 2 left panel. The fall was approximately 8' x 8' x 3' thick.

  24. Non-Injury Accident Investigation

    inspectionRecord 6320136

    4.0 on-site hours reported

  25. Violation — cited standard not reported

    violationRecord 9847563
Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.