Sweetwater Mine/Mill safety activity
MSHA violations, accident reports and inspections.
Safety activity
Inspection.
30 CFR 57.4201(a)(2)
Inspection and cover plates.
30 CFR 57.12032
Safety defects; examination, correction and records.
30 CFR 57.14100(c) · Significant and substantial (S&S)
Spillage and leakage.
30 CFR 57.4102 · Significant and substantial (S&S)
Inspection and cover plates.
30 CFR 57.12032
Insulation and fittings for power wires and cables.
30 CFR 57.12008
Regular Safety and Health Inspection
9.8 on-site hours reported
Powered haulage
Days away from work only
Accident narrative
SCALING THE BACK, HOOKED ON A LIP AND JOLTED EMPLOYEE WHEN IT GAVE WAY.
Impoundment Spot Inspection
0.0 on-site hours reported
Non-Injury Accident Investigation
5.0 on-site hours reported
Non-Fatal Accident Investigation
58.3 on-site hours reported
Violation — cited standard not reported
Verbal Hazard Complaint Inspections
5.0 on-site hours reported
Moving machine parts.
30 CFR 57.14107(a)
Electrical conductors.
30 CFR 57.12004
Electrical conductors.
30 CFR 57.12004 · $151.00 proposed penalty
Separation of transported explosive material.
30 CFR 57.6201(a)(2) · $504.00 proposed penalty
Safety defects; examination, correction and records.
30 CFR 57.14100(b) · $504.00 proposed penalty
Stationary grinding machines.
30 CFR 57.14115(b) · $151.00 proposed penalty
Guarding electrical connections and resistor grids.
30 CFR 57.12023 · $504.00 proposed penalty
Testing grounding systems.
30 CFR 57.12028 · $336.00 proposed penalty
Identification of power switches.
30 CFR 57.12018 · $504.00 proposed penalty
Safety defects; examination, correction and records.
30 CFR 57.14100(b) · $549.00 proposed penalty
Temporary, portable containers.
30 CFR 47.44(b) · $226.00 proposed penalty
Correction of hazardous conditions.
30 CFR 57.3200 · $504.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.