← Stonecoal Branch Mine No. 2

Stonecoal Branch Mine No. 2 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Methane monitors.

    violationRecord 5091321

    30 CFR 75.342(a)(4) · $177.00 proposed penalty

  2. Accumulation of combustible materials.

    violationRecord 5091320

    30 CFR 75.400 · $755.00 proposed penalty

  3. Permissible electric face equipment; maintenance.

    violationRecord 5091319

    30 CFR 75.503 · $226.00 proposed penalty

  4. Drill dust control at underground areas of underground mines.

    violationRecord 5091318

    30 CFR 72.630(b) · $209.00 proposed penalty

  5. Slip or fall of person

    accidentRecord 220251470003

    Days away from work only

    Accident narrative

    Employee stepped down from the roof bolter when EE felt a pain in EE's leg, causing EE to fall.

  6. Protection from falls of roof, face and ribs.

    violationRecord 9838358

    30 CFR 75.202(a) · Significant and substantial (S&S) · $3,448.00 proposed penalty

  7. Other safeguards.

    violationRecord 9838357

    30 CFR 75.1403

  8. Condition and examination of firefighting equipment.

    violationRecord 5091317

    30 CFR 75.1100-3 · $366.00 proposed penalty

  9. Protection from falls of roof, face and ribs.

    violationRecord 5091316

    30 CFR 75.202(a) · Significant and substantial (S&S) · $3,448.00 proposed penalty

  10. Approval of other fire suppression devices.

    violationRecord 5091315

    30 CFR 75.1107-13(g) · $151.00 proposed penalty

  11. Inspection of fire suppression devices.

    violationRecord 5091314

    30 CFR 75.1107-16(b) · $226.00 proposed penalty

  12. Other safeguards.

    violationRecord 9839958

    30 CFR 75.1403 · $592.00 proposed penalty

  13. Accumulation of combustible materials.

    violationRecord 5091313

    30 CFR 75.400 · $755.00 proposed penalty

  14. Grounding metallic frames, casings, and other enclosures of electric equipment.

    violationRecord 5091312

    30 CFR 75.701 · $366.00 proposed penalty

  15. Permissible electric face equipment; maintenance.

    violationRecord 5091311

    30 CFR 75.503 · $504.00 proposed penalty

  16. Multi-gas detectors.

    violationRecord 9839384

    30 CFR 75.1714-7(b) · $1,126.00 proposed penalty

  17. Use of insulated cable handling equipment.

    violationRecord 9839383

    30 CFR 75.818(b)(4) · $465.00 proposed penalty

  18. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9839382

    30 CFR 75.1731(b) · $465.00 proposed penalty

  19. Automatic fire sensors.

    violationRecord 9839381

    30 CFR 75.1103-1(b) · $1,037.00 proposed penalty

  20. Protection from falls of roof, face and ribs.

    violationRecord 9839380

    30 CFR 75.202(a) · Significant and substantial (S&S) · $2,312.00 proposed penalty

  21. Power wires and cables; insulation and protection.

    violationRecord 5091310

    30 CFR 75.517 · Significant and substantial (S&S) · $7,676.00 proposed penalty

  22. Automatic fire sensors.

    violationRecord 5091309

    30 CFR 75.1103-1(b) · $151.00 proposed penalty

  23. Roof bolting.

    violationRecord 5091308

    30 CFR 75.204(c)(1) · $398.00 proposed penalty

  24. Permissible electric face equipment; maintenance.

    violationRecord 9837095

    30 CFR 75.503 · $267.00 proposed penalty

  25. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9839266

    30 CFR 75.1731(b) · $465.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.