← ROAD FORK #52 MINE

ROAD FORK #52 MINE safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Protection from falls of roof, face and ribs.

    violationRecord 5134605

    30 CFR 75.202(a) · Significant and substantial (S&S) · $3,184.00 proposed penalty

  2. Permissible electric face equipment; maintenance.

    violationRecord 5134604

    30 CFR 75.503 · $267.00 proposed penalty

  3. Permissible electric face equipment; maintenance.

    violationRecord 5134603

    30 CFR 75.503 · $592.00 proposed penalty

  4. Spot Inspections

    inspectionRecord F036048

    103(i) · 4.0 on-site hours reported

  5. Ventilation controls.

    violationRecord 5134602

    30 CFR 75.333(c) · $336.00 proposed penalty

  6. Accumulation of combustible materials.

    violationRecord 5134601

    30 CFR 75.400 · $755.00 proposed penalty

  7. Disorders (physical agents)

    accidentRecord 220262530007

    Occupatnal illness not deg 1-6

    Accident narrative

    Employee did not incur an occupational injury. EE suffered a non-work-related medical event while standing beside a roof bolter. Employee was treated by EMS paramedic and taken to a local hospital, treated for dehydration and low blood sugar. We are submitting this report to abate citation number 5134629 and this report is to be classified as Degree 8 with (0) lost work days.

  8. Spot Inspections

    inspectionRecord F036047

    103(i) · 5.5 on-site hours reported

  9. Protection from falls of roof, face and ribs.

    violationRecord 5094511

    30 CFR 75.202(a) · Significant and substantial (S&S) · $10,569.00 proposed penalty

  10. Electric equipment; examination, testing and maintenance.

    violationRecord 5134600

    30 CFR 75.512 · $313.00 proposed penalty

  11. Permissible electric face equipment; maintenance.

    violationRecord 5132599

    30 CFR 75.503 · $592.00 proposed penalty

  12. Machinery and equipment; operation and maintenance.

    violationRecord 5132598

    30 CFR 75.1725(a) · Significant and substantial (S&S)

  13. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 5096689

    30 CFR 75.1714-3(a) · $1,431.00 proposed penalty

  14. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 5096687

    30 CFR 75.1714-3(a) · $1,431.00 proposed penalty

  15. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 5096686

    30 CFR 75.1714-3(a) · $1,126.00 proposed penalty

  16. Spot Inspections

    inspectionRecord F036046

    103(i) · 6.0 on-site hours reported

  17. Roof control plan.

    violationRecord 5094510

    30 CFR 75.220(a)(1) · $1,126.00 proposed penalty

  18. Ventilation controls.

    violationRecord 5094509

    30 CFR 75.333(d)(3) · $151.00 proposed penalty

  19. Accumulation of combustible materials.

    violationRecord 5132596

    30 CFR 75.400 · $755.00 proposed penalty

  20. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 5132595

    30 CFR 75.1731(a) · $151.00 proposed penalty

  21. Mine ventilation plan; submission and approval.

    violationRecord 5132594

    30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $2,503.00 proposed penalty

  22. Dust disease of lungs

    accidentRecord 220262230005

    Occupatnal illness not deg 1-6

    Accident narrative

    The miner has been diagnosed with occupational pneumoconiosis.

  23. Dust disease of lungs

    accidentRecord 220262230007

    Occupatnal illness not deg 1-6

    Accident narrative

    The miner has been diagnosed with occupational pneumoconiosis.

  24. Verbal Hazard Complaint Inspections

    inspectionRecord F011550

    27.3 on-site hours reported

  25. Mechanical equipment guards.

    violationRecord 5133298

    30 CFR 75.1722(a) · Significant and substantial (S&S) · $2,712.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.