← Prairie Eagle-Underground

Prairie Eagle-Underground safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Communications facilities; refuge alternatives.

    violationRecord 9786524

    30 CFR 75.1600-3(a)(1) · $226.00 proposed penalty

  2. Power-driven pulleys.

    violationRecord 9549744

    30 CFR 77.407(a) · $226.00 proposed penalty

  3. Maintenance of diesel-powered equipment.

    violationRecord 9549743

    30 CFR 75.1914(a) · Significant and substantial (S&S) · $4,383.00 proposed penalty

  4. Slip or fall of person

    accidentRecord 220250590018

    No dys awy frm wrk,no rstr act

    Accident narrative

    I.E. was putting a 6' bolt and glue into a hole. As they were pushing the bolt into the hole, they slipped causing them to lose grip of the bolt. The bolt fell from the roof hit the wrench and struck the I.E. above the eye. The laceration required stitches and the I.E. did not miss any work.

  5. Protection from falls of roof, face and ribs.

    violationRecord 9786729

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,818.00 proposed penalty

  6. Protection from falls of roof, face and ribs.

    violationRecord 9786728

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,818.00 proposed penalty

  7. Non-Injury Accident Investigation

    inspectionRecord F005C20

    1.0 on-site hours reported

  8. Inundation

    accidentRecord 220250550029

    Accident only

    Accident narrative

    The main water supply pipe coming into the mine busted causing excessive water to accumulate at the mouth of the mine impeding one escapeway.

  9. Fall of roof or back

    accidentRecord 220250520020

    Accident only

    Accident narrative

    A roof fall occurred at this location on 2-20-2025. The fall location was the 2 South Entry 5 31+40 survey station. The fall measured 15 feet wide, 38 feet long, and 5-6 feet high. No one was injured.

  10. Non-Injury Accident Investigation

    inspectionRecord F005C1F

    14.0 on-site hours reported

  11. Roof control plan.

    violationRecord 9786523

    30 CFR 75.220(a)(1) · $336.00 proposed penalty

  12. Violation — cited standard not reported

    violationRecord 9786522
  13. Spot Inspections

    inspectionRecord F005A39

    103(i) · 4.5 on-site hours reported

  14. Clamping of trailing cables to equipment.

    violationRecord 9786521

    30 CFR 75.605 · $226.00 proposed penalty

  15. Maintenance of incombustible content of rock dust.

    violationRecord 9783950

    30 CFR 75.403 · $245.00 proposed penalty

  16. Nonpermissible diesel-powered equipment; design and performance requirements.

    violationRecord 9786727

    30 CFR 75.1909(b)(6) · $2,312.00 proposed penalty

  17. Methane monitors.

    violationRecord 9783949

    30 CFR 75.342(a)(4) · $165.00 proposed penalty

  18. Mine ventilation plan; submission and approval.

    violationRecord 9541068

    30 CFR 75.370(a)(1) · $267.00 proposed penalty

  19. Disconnecting devices.

    violationRecord 9786726

    30 CFR 75.903 · $755.00 proposed penalty

  20. Protection from falls of roof, face and ribs.

    violationRecord 9786725

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,818.00 proposed penalty

  21. Methane monitors.

    violationRecord 9786724

    30 CFR 75.342(a)(4) · $177.00 proposed penalty

  22. Roof control plan.

    violationRecord 9786723

    30 CFR 75.220(a)(1) · $336.00 proposed penalty

  23. Escapeway maps.

    violationRecord 9786722

    30 CFR 75.1505(b) · $151.00 proposed penalty

  24. Spot Inspections

    inspectionRecord F005C1E

    103(i) · 6.5 on-site hours reported

  25. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9786721

    30 CFR 75.1731(a) · Significant and substantial (S&S) · $1,219.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.