← Prairie Eagle-Underground

Prairie Eagle-Underground safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Protection from falls of roof, face and ribs.

    violationRecord 9789621

    30 CFR 75.202(a) · $1,126.00 proposed penalty

  2. Maintenance of diesel-powered equipment.

    violationRecord 9789620

    30 CFR 75.1914(a) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  3. Permissible electric face equipment; maintenance.

    violationRecord 9546087

    30 CFR 75.503 · $336.00 proposed penalty

  4. Permissible electric face equipment; maintenance.

    violationRecord 5011625

    30 CFR 75.503 · $336.00 proposed penalty

  5. Ground control; inspection and maintenance; general.

    violationRecord 9789619

    30 CFR 77.1004(b) · $755.00 proposed penalty

  6. Protection from falls of roof, face and ribs.

    violationRecord 9789618

    30 CFR 75.202(a) · $336.00 proposed penalty

  7. Roof control plan.

    violationRecord 9789617

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $6,037.00 proposed penalty

  8. Electric equipment; examination, testing, and maintenance.

    violationRecord 9789616

    30 CFR 77.502 · $226.00 proposed penalty

  9. Electric equipment; examination, testing, and maintenance.

    violationRecord 9789615

    30 CFR 77.502 · $151.00 proposed penalty

  10. Accumulation of combustible materials.

    violationRecord 5011624

    30 CFR 75.400 · $432.00 proposed penalty

  11. Electric equipment; examination, testing and maintenance.

    violationRecord 9789614

    30 CFR 75.512 · $1,219.00 proposed penalty

  12. Roof control plan.

    violationRecord 9789613

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $20,047.00 proposed penalty

  13. Protection from falls of roof, face and ribs.

    violationRecord 9789612

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  14. Protection from falls of roof, face and ribs.

    violationRecord 9789611

    30 CFR 75.202(a) · Significant and substantial (S&S) · $18,504.00 proposed penalty

  15. Maintenance of diesel-powered equipment.

    violationRecord 5011623

    30 CFR 75.1914(a) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  16. Spot Inspections

    inspectionRecord 7031399

    103(i) · 5.3 on-site hours reported

  17. Fire suppression systems for diesel-powered equipment and fuel transportation units.

    violationRecord 9789610

    30 CFR 75.1911(d) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  18. Ventilation controls.

    violationRecord 5011622

    30 CFR 75.333(h) · $245.00 proposed penalty

  19. Handling of materials

    accidentRecord 220252260018

    Days away from work only

    Accident narrative

    I.E. was lifting rub rail on continuous miner to put back into place. As the I.E. raised the bar they felt a pop in their left elbow. I.E. continued to work until doctor's restrictions took them off work on 8/7/2025.

  20. Non-Injury Accident Investigation

    inspectionRecord 7031398

    5.8 on-site hours reported

  21. Violation — cited standard not reported

    violationRecord 9789609
  22. Fall of roof or back

    accidentRecord 220252270013

    Accident only

    Accident narrative

    A roof fall occurred at this location on 8-5-2025. The fall location was on the 2nd East in entry #5 in the intersection at survey station 12+00. The fall measured 20ft wide, 40 ft long, and 6-7ft high. No one was injured.

  23. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9789608

    30 CFR 75.1731(b) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  24. Protection from falls of roof, face and ribs.

    violationRecord 9789607

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  25. Protection from falls of roof, face and ribs.

    violationRecord 5011618

    30 CFR 75.202(a) · $336.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.