← Oaktown Fuels Mine No. 1

Oaktown Fuels Mine No. 1 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Power wires and cables; insulation and protection.

    violationRecord 9785561

    30 CFR 75.517 · $267.00 proposed penalty

  2. Spot Inspections

    inspectionRecord F01B937

    103(i) · 7.5 on-site hours reported

  3. Roof control plan.

    violationRecord 9785560

    30 CFR 75.220(a)(1) · $818.00 proposed penalty

  4. Mine ventilation plan; submission and approval.

    violationRecord 9785559

    30 CFR 75.370(a)(1) · $151.00 proposed penalty

  5. Other safeguards.

    violationRecord 9785558

    30 CFR 75.1403 · $592.00 proposed penalty

  6. Spot Inspections

    inspectionRecord F0070C4

    103(i) · 7.3 on-site hours reported

  7. Ventilation controls.

    violationRecord 9785557

    30 CFR 75.333(b)(2) · $177.00 proposed penalty

  8. Ventilation controls.

    violationRecord 9785556

    30 CFR 75.333(b)(2) · $177.00 proposed penalty

  9. Permissible electric face equipment; maintenance.

    violationRecord 9785555

    30 CFR 75.503 · $151.00 proposed penalty

  10. Maintenance of incombustible content of rock dust.

    violationRecord 9785554

    30 CFR 75.403 · $151.00 proposed penalty

  11. Maintenance of incombustible content of rock dust.

    violationRecord 9785553

    30 CFR 75.403 · $151.00 proposed penalty

  12. Spot Inspections

    inspectionRecord F019527

    103(i) · 5.8 on-site hours reported

  13. Fall of roof or back

    accidentRecord 220260350059

    Accident only

    Accident narrative

    on 1/29/2026 an unintentional roof fall occurred on the #35 cross cut entry #5(belt line)of the 2C. The fall is approximately 20 foot in length, 28 foot wide, and 15 foot thick. It is believed that water deteriorated the upper strata making it unstable, causing it to fall.

  14. Non-Injury Accident Investigation

    inspectionRecord F01B936

    12.8 on-site hours reported

  15. Violation — cited standard not reported

    violationRecord 9785552
  16. Fire suppression systems for diesel-powered equipment and fuel transportation units.

    violationRecord 9785551

    30 CFR 75.1911(i) · Significant and substantial (S&S) · $432.00 proposed penalty

  17. Spot Inspections

    inspectionRecord F01B935

    103(i) · 5.3 on-site hours reported

  18. Permissible electric face equipment; maintenance.

    violationRecord 9785550

    30 CFR 75.503 · $366.00 proposed penalty

  19. Spot Inspections

    inspectionRecord F019526

    103(i) · 5.5 on-site hours reported

  20. Maintenance and tests of liquefied and nonliquefied compressed gas cylinders; accessories and equipment; requirements.

    violationRecord 9785549

    30 CFR 75.1106-5(a) · $151.00 proposed penalty

  21. Roof control plan.

    violationRecord 9785548

    30 CFR 75.220(a)(1) · $226.00 proposed penalty

  22. Ventilation controls.

    violationRecord 9785547

    30 CFR 75.333(c)(3) · $151.00 proposed penalty

  23. Permissible electric face equipment; maintenance.

    violationRecord 9785546

    30 CFR 75.503 · Significant and substantial (S&S) · $592.00 proposed penalty

  24. Stepping or kneeling on object

    accidentRecord 220260230003

    Days restricted activity only

    Accident narrative

    Employee was taking down fire suppression above a scoop charger. When employee stepped off charger EE stepped on rock, rolling EE's ankle. Ankle was found to be sprained and the employee was put on restrictions (mainly sit down work only) and placed in a walking boot.

  25. Other

    accidentRecord 220260440016

    Dys awy frm wrk & restrctd act

    Accident narrative

    Employee was working on a battery coal hauler in diesel shop when they stepped up on the coal hauler tail-gate with right leg and felt left knee pop. On 2/6/2026 we were advised they had a meniscal tear and was placed on restrictions (No Kneeling).

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.