No. 8 safety activity
MSHA violations, accident reports and inspections.
Safety activity
Main mine fan examinations and records.
30 CFR 75.312(b)(1)(i)
Permissible electric face equipment; maintenance.
30 CFR 75.503
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S)
Permissible electric face equipment; maintenance.
30 CFR 75.503
Other safeguards.
30 CFR 75.1403 · Significant and substantial (S&S)
Preshift examination at fixed intervals.
30 CFR 75.360(g)
Handling of materials
No dys awy frm wrk,no rstr act
Accident narrative
Was changing scoop batteries and the lid came down on hand.
Electric wiring and equipment; installation and maintenance.
30 CFR 77.516
Cable fittings; suitability.
30 CFR 77.505
Grounding metallic frames, casings, and other enclosures of electric equipment.
30 CFR 77.701
Powered haulage
Days away from work only
Accident narrative
IE was pushing gob into a crosscut with a scoop. A waterline in the entry was struck by the scoop, and a broken end struck IE in the arm and abdomen as EE operated the scoop from the cab.
Powered haulage
Days away from work only
Accident narrative
Was cleaning with scoop and was hit with piece of waterline.
Preshift examination at fixed intervals.
30 CFR 75.360(b)(3) · Significant and substantial (S&S)
Roof control plan.
30 CFR 75.220(a)(1) · Significant and substantial (S&S)
Regular Safety and Health Inspection
38.0 on-site hours reported
Verbal Hazard Complaint Inspections
6.0 on-site hours reported
Handtools (nonpowered)
No dys awy frm wrk,no rstr act
Accident narrative
cut hand
Verbal Hazard Complaint Inspections
15.0 on-site hours reported
Spot Inspection
12.5 on-site hours reported
Verbal Hazard Complaint Inspections
7.0 on-site hours reported
Roof control plan.
30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $465.00 proposed penalty
Roof control plan.
30 CFR 75.220(a)(1) · $151.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $151.00 proposed penalty
Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.
30 CFR 75.1600-2(b) · $151.00 proposed penalty
Power wires; support.
30 CFR 75.516 · $151.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.