← No 7 Mine

No 7 Mine safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Preshift examination at fixed intervals.

    violationRecord 5061820

    30 CFR 75.360(g) · $151.00 proposed penalty

  2. Accumulation of combustible materials.

    violationRecord 9827125

    30 CFR 75.400 · $465.00 proposed penalty

  3. Roof control plan.

    violationRecord 9827124

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $1,818.00 proposed penalty

  4. Mine ventilation plan; submission and approval.

    violationRecord 9827123

    30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $1,431.00 proposed penalty

  5. Escapeways; bituminous and lignite mines.

    violationRecord 9827122

    30 CFR 75.380(d)(7)(vi) · $336.00 proposed penalty

  6. Accumulations of combustible materials.

    violationRecord 9631791

    30 CFR 77.1104 · Significant and substantial (S&S) · $1,126.00 proposed penalty

  7. Spot Inspections

    inspectionRecord F02E10A

    103(i) · 9.3 on-site hours reported

  8. Protection from falls of roof, face and ribs.

    violationRecord 5063005

    30 CFR 75.202(a) · $398.00 proposed penalty

  9. Roof control plan.

    violationRecord 9827121

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $1,818.00 proposed penalty

  10. Ventilation controls.

    violationRecord 9827120

    30 CFR 75.333(c)(3) · $226.00 proposed penalty

  11. Spot Inspections

    inspectionRecord F02E109

    103(i) · 10.5 on-site hours reported

  12. Permissible electric face equipment; maintenance.

    violationRecord 5063004

    30 CFR 75.503 · Significant and substantial (S&S) · $1,550.00 proposed penalty

  13. Quantity and location of firefighting equipment.

    violationRecord 9821740

    30 CFR 75.1100-2(b) · $465.00 proposed penalty

  14. Machinery and equipment; operation and maintenance.

    violationRecord 9821739

    30 CFR 75.1725(a) · Significant and substantial (S&S) · $1,320.00 proposed penalty

  15. Electric equipment; examination, testing, and maintenance.

    violationRecord 9756566

    30 CFR 77.502 · $755.00 proposed penalty

  16. Mechanical equipment guards.

    violationRecord 5063003

    30 CFR 77.400(d) · $226.00 proposed penalty

  17. Electric equipment; examination, testing, and maintenance.

    violationRecord 9756565

    30 CFR 77.502 · $226.00 proposed penalty

  18. Non-Injury Accident Investigation

    inspectionRecord 6920856

    10.8 on-site hours reported

  19. Protection from falls of roof, face and ribs.

    violationRecord 9824137

    30 CFR 75.202(a) · Significant and substantial (S&S) · $6,540.00 proposed penalty

  20. Violation — cited standard not reported

    violationRecord 9824136
  21. Attachment of ground conductors and ground check wires to equipment frames; use of separate connections.

    violationRecord 9821738

    30 CFR 75.902-4 · $226.00 proposed penalty

  22. Preshift examination at fixed intervals.

    violationRecord 9821737

    30 CFR 75.360(f) · $226.00 proposed penalty

  23. Protection from falls of roof, face and ribs.

    violationRecord 9821736

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,968.00 proposed penalty

  24. Fall of roof or back

    accidentRecord 220251330010

    Accident only

    Accident narrative

    A Unplanned Roof Fall Occurred On NE-9 (#8 Section) At Crosscut Number 49 In The Long Crosscut Between The #2 Track Entry And The #3 Belt Entry. The Mine Roof Fell Above The Anchorage Point Of The Primary Roof Support. The Roof Fall Occurred Due To Undetected Separation With Laminations Above The Anchorage Point Of The Primary Roof Support Installed During Development.

  25. Electric equipment; examination, testing and maintenance.

    violationRecord 9827119

    30 CFR 75.512 · $245.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.