← No 4 Mine

No 4 Mine safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Methane monitors.

    violationRecord 9757512

    30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $1,679.00 proposed penalty

  2. Roof Control Technical Investigation

    inspectionRecord 6920862

    52.0 on-site hours reported

  3. Regular Safety and Health Inspection

    inspectionRecord 6972384

    660.8 on-site hours reported

  4. Spot Inspections

    inspectionRecord F025C13

    103(i) · 5.0 on-site hours reported

  5. Mine ventilation plan; submission and approval.

    violationRecord 5061438

    30 CFR 75.370(a)(1) · $288.00 proposed penalty

  6. Atmospheric monitoring systems.

    violationRecord 5061437

    30 CFR 75.351(k) · $288.00 proposed penalty

  7. Slip or fall of person

    accidentRecord 220251780020

    Days away from work only

    Accident narrative

    Employee was hanging blowing curtain in the #1 Entry on #4 Section when they stepped into an uneven area (rut) with some loose rock and twisted right knee and felt a pop causing a tibial plateau fracture in right knee.

  8. Spot Inspections

    inspectionRecord F014C08

    103(i) · 9.3 on-site hours reported

  9. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 5062496

    30 CFR 75.1714-3(a) · $432.00 proposed penalty

  10. Other safeguards.

    violationRecord 5062495

    30 CFR 75.1403 · $336.00 proposed penalty

  11. Maintenance of diesel-powered equipment.

    violationRecord 5062494

    30 CFR 75.1914(a) · $288.00 proposed penalty

  12. Power wires and cables; insulation and protection.

    violationRecord 5062493

    30 CFR 75.517 · Significant and substantial (S&S) · $1,550.00 proposed penalty

  13. Power wires and cables; insulation and protection.

    violationRecord 5062492

    30 CFR 75.517 · Significant and substantial (S&S) · $1,550.00 proposed penalty

  14. Mine ventilation plan; submission and approval.

    violationRecord 5062491

    30 CFR 75.370(a)(1) · $151.00 proposed penalty

  15. Protection from falls of roof, face and ribs.

    violationRecord 5062490

    30 CFR 75.202(a) · $549.00 proposed penalty

  16. Roof control plan.

    violationRecord 5062489

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $2,712.00 proposed penalty

  17. Ventilation controls.

    violationRecord 5061436

    30 CFR 75.333(h) · $549.00 proposed penalty

  18. Slip or fall of person

    accidentRecord 220251750013

    Days away from work only

    Accident narrative

    Employee was walking outby on 4 West #1 Belt checking for splices around XC #112 when they tripped over a rock in the walkway going over the old overcast and fell into the walk side of the belt structure and top side roller and caught their right arm between the belt and the roller causing a fracture/abrasion to their right lower arm and a contusion to the right elbow.

  19. Fall of roof or back

    accidentRecord 220251750009

    Accident only

    Accident narrative

    Intersection #112 in the #5 entry of the 4 West N-Panel seal line, was an old fault area that had a mixture of 4' resin bolts and 8' cable bolts with mesh in some areas along with some straps. It fell out just above the anchorage point of the resin pins with some of the cable bolts still hanging showing they were still secured in good roof.

  20. Spot Inspections

    inspectionRecord F025C12

    103(i) · 8.3 on-site hours reported

  21. Maintenance of incombustible content of rock dust.

    violationRecord 9824156

    30 CFR 75.403 · $432.00 proposed penalty

  22. Maintenance of incombustible content of rock dust.

    violationRecord 9824155

    30 CFR 75.403 · $432.00 proposed penalty

  23. Maintenance of incombustible content of rock dust.

    violationRecord 9824154

    30 CFR 75.403 · $432.00 proposed penalty

  24. Multi-gas detectors.

    violationRecord 5062488

    30 CFR 75.1714-7(a) · $313.00 proposed penalty

  25. Nonpermissible diesel-powered equipment; electrical system design and performance requirements.

    violationRecord 5061435

    30 CFR 75.1910(l) · $245.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.