Safety activity

  1. Mine ventilation plan; submission and approval.

    violationRecord 5191421

    30 CFR 75.370(a)(1) · $465.00 proposed penalty

  2. Quantity and location of firefighting equipment.

    violationRecord 5191420

    30 CFR 75.1100-2(f) · $245.00 proposed penalty

  3. Maintenance of incombustible content of rock dust.

    violationRecord 5191419

    30 CFR 75.403 · $642.00 proposed penalty

  4. Maintenance of incombustible content of rock dust.

    violationRecord 5191418

    30 CFR 75.403 · $642.00 proposed penalty

  5. Maintenance of incombustible content of rock dust.

    violationRecord 5191417

    30 CFR 75.403 · $642.00 proposed penalty

  6. Maintenance of incombustible content of rock dust.

    violationRecord 5191416

    30 CFR 75.403 · $642.00 proposed penalty

  7. Mechanical equipment guards.

    violationRecord 5069163

    30 CFR 77.400(d) · $366.00 proposed penalty

  8. Mechanical equipment guards.

    violationRecord 5069072

    30 CFR 77.400(d) · $366.00 proposed penalty

  9. Spot Inspections

    inspectionRecord F01A742

    103(i) · 6.3 on-site hours reported

  10. Spot Inspections

    inspectionRecord F01A741

    103(i) · 2.0 on-site hours reported

  11. Accumulation of combustible materials.

    violationRecord 5191415

    30 CFR 75.400 · $465.00 proposed penalty

  12. Roof control plan.

    violationRecord 5191413

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $2,312.00 proposed penalty

  13. Protection from falls of roof, face and ribs.

    violationRecord 5062750

    30 CFR 75.202(a) · Significant and substantial (S&S) · $2,312.00 proposed penalty

  14. Accumulation of combustible materials.

    violationRecord 5191231

    30 CFR 75.400 · $465.00 proposed penalty

  15. Protection from falls of roof, face and ribs.

    violationRecord 5063821

    30 CFR 75.202(a) · Significant and substantial (S&S) · $2,312.00 proposed penalty

  16. Spot Inspections

    inspectionRecord F01A740

    103(i) · 7.0 on-site hours reported

  17. Protection from falls of roof, face and ribs.

    violationRecord 5191412

    30 CFR 75.202(a) · Significant and substantial (S&S) · $2,312.00 proposed penalty

  18. Roof bolting.

    violationRecord 5191411

    30 CFR 75.204(c)(1) · $245.00 proposed penalty

  19. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 5062749

    30 CFR 75.1714-3(a) · $818.00 proposed penalty

  20. Other safeguards.

    violationRecord 5062748

    30 CFR 75.1403 · $245.00 proposed penalty

  21. Electric equipment other than power-connection points; outby the last open crosscut; return air; permissibility requirements.

    violationRecord 5191410

    30 CFR 75.507-1(a) · Significant and substantial (S&S) · $1,320.00 proposed penalty

  22. Protection from falls of roof, face and ribs.

    violationRecord 5062747

    30 CFR 75.202(a) · $504.00 proposed penalty

  23. Machinery

    accidentRecord 220260490013

    Days away from work only

    Accident narrative

    Employee was moving pan line to C-5 and, while attempting to re-rail a wrecked car, the track jack dislodged from underneath the car and struck their left hand, resulting in two fractures and a laceration to left little (5th) finger.

  24. Verbal Hazard Complaint Inspections

    inspectionRecord F01A73E

    1.5 on-site hours reported

  25. Spot Inspections

    inspectionRecord F01A73F

    103(i) · 7.0 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.