Morton Salt Fairport Mine safety activity
MSHA violations, accident reports and inspections.
Safety activity
Housekeeping.
30 CFR 57.20003(a) · $151.00 proposed penalty
Housekeeping.
30 CFR 57.20003(a) · $151.00 proposed penalty
Combustible waste.
30 CFR 57.4104(a) · $151.00 proposed penalty
Powered haulage
Dys awy frm wrk & restrctd act
Accident narrative
Employee reported neck pain while using an LHD to clean up faces for drills and augers. Upon evaluation, the employee was diagnosed with a fracture. Work relatedness determination was made on 12/29/2025.
Parking procedures for unattended equipment.
30 CFR 57.14207 · $151.00 proposed penalty
Housekeeping.
30 CFR 57.20003(a) · $151.00 proposed penalty
Regular Safety and Health Inspection
118.8 on-site hours reported
Hoisting
Accident only
Accident narrative
Electrical contactor failed causing the production hoist to be unavailable for operation.
Hoisting
Accident only
Accident narrative
Nopak valve for south gate failed causing the production hoist to be unavailable.
Hoisting
Accident only
Accident narrative
Work deck contacting brackets causing the production hoist to be inoperable.
Hoisting
Accident only
Accident narrative
Material came loose from the North liner. Shutdown hoist to inspect shaft.
Electrical conductors.
30 CFR 57.12004 · $151.00 proposed penalty
Inspection.
30 CFR 57.4201(a)(1) · $151.00 proposed penalty
Regular Safety and Health Inspection
82.3 on-site hours reported
Construction and maintenance of guards.
30 CFR 57.14112(a)(2) · $151.00 proposed penalty
Housekeeping.
30 CFR 57.20003(a) · $151.00 proposed penalty
Correction of hazardous conditions.
30 CFR 57.3200 · $151.00 proposed penalty
Hoisting
Accident only
Accident narrative
The dynamic brakes faulted out causing the production hoist to be inoperable. Found switch in hoist operators booth in automatic.
Hoisting
Accident only
Accident narrative
Production skip components failed causing the hoist to be unavailable for egress.
Hoisting
Accident only
Accident narrative
Electrical contactor failed on the production hoist causing the hoist to be inoperable.
Hoisting
Accident only
Accident narrative
The over travel switch malfunctioned causing the service hoist to be unavailable. EVAC was canceled.
Identification of power switches.
30 CFR 57.12018 · $151.00 proposed penalty
Identification of power switches.
30 CFR 57.12018 · $151.00 proposed penalty
Electrical conductors.
30 CFR 57.12004 · $151.00 proposed penalty
Construction and maintenance of guards.
30 CFR 57.14112(b) · $151.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.