← Lower War Eagle

Lower War Eagle safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-28Database snapshot · 2026-10-28

Safety activity

  1. On-shift examination.

    violationRecord 5097988

    30 CFR 75.362(g)(3) · $151.00 proposed penalty

  2. Spot Inspections

    inspectionRecord F005E8A

    103(i) · 5.5 on-site hours reported

  3. Regular Safety and Health Inspection

    inspectionRecord F005EB2

    63.0 on-site hours reported

  4. Spot Inspections

    inspectionRecord 7047944

    103(i) · 6.3 on-site hours reported

  5. Spot Inspection

    inspectionRecord F0219D0

    5.3 on-site hours reported

  6. Spot Inspections

    inspectionRecord F0219D3

    103(i) · 4.3 on-site hours reported

  7. Roof control plan.

    violationRecord 5097980

    30 CFR 75.220(a)(1) · $151.00 proposed penalty

  8. Records of training.

    violationRecord 5132040

    30 CFR 48.29(c) · $151.00 proposed penalty

  9. Audiometric test procedures.

    violationRecord 5132039

    30 CFR 62.171(c) · $151.00 proposed penalty

  10. Spot Inspections

    inspectionRecord F010DF5

    103(i) · 5.0 on-site hours reported

  11. Other safeguards.

    violationRecord 5132038

    30 CFR 75.1403 · Significant and substantial (S&S) · $1,037.00 proposed penalty

  12. Other safeguards.

    violationRecord 5132037

    30 CFR 75.1403 · Significant and substantial (S&S) · $1,037.00 proposed penalty

  13. Roof control plan.

    violationRecord 5132036

    30 CFR 75.220(a)(1) · Significant and substantial (S&S) · $697.00 proposed penalty

  14. Spot Inspections

    inspectionRecord 7047941

    103(i) · 8.8 on-site hours reported

  15. Other safeguards.

    violationRecord 5132035

    30 CFR 75.1403 · Significant and substantial (S&S) · $1,550.00 proposed penalty

  16. Ventilation controls.

    violationRecord 5132034

    30 CFR 75.333(e)(1)(ii) · $165.00 proposed penalty

  17. Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.

    violationRecord 5132033

    30 CFR 75.1107-1(a)(3)(ii) · $165.00 proposed penalty

  18. Maintenance of incombustible content of rock dust.

    violationRecord 5132031

    30 CFR 75.403 · $151.00 proposed penalty

  19. Power wires; support.

    violationRecord 5132028

    30 CFR 75.516 · $165.00 proposed penalty

  20. Protection from falls of roof, face and ribs.

    violationRecord 5132027

    30 CFR 75.202(a) · $209.00 proposed penalty

  21. Spot Inspections

    inspectionRecord F0219CD

    103(i) · 7.0 on-site hours reported

  22. Machinery and equipment; operation and maintenance.

    violationRecord 5097967

    30 CFR 75.1725(a) · $151.00 proposed penalty

  23. Preshift examination at fixed intervals.

    violationRecord 5097966

    30 CFR 75.360(g) · $151.00 proposed penalty

  24. Flammable liquids; storage.

    violationRecord 5132026

    30 CFR 77.1103(d) · $151.00 proposed penalty

  25. Spot Inspections

    inspectionRecord F010DEE

    103(i) · 9.0 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.