← LONGVIEW MINE

LONGVIEW MINE safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Protective clothing; requirements.

    violationRecord 5120654

    30 CFR 77.1710(c)

  2. Spot Inspections

    inspectionRecord F0463DA

    103(i) · 6.0 on-site hours reported

  3. Handtools (nonpowered)

    accidentRecord 220263000020

    No dys awy frm wrk,no rstr act

    Accident narrative

    Injured employee stated that while cutting the bands on a bundle of cable bolts they sustained a laceration to left thumb requiring sutures to close. No scheduled shifts were missed as a result of the incident.

  4. Electrical Technical Investigation

    inspectionRecord F0136C6

    5.0 on-site hours reported

  5. Spot Inspections

    inspectionRecord F0463D9

    103(i) · 3.3 on-site hours reported

  6. Spot Inspections

    inspectionRecord F0463D8

    103(i) · 7.5 on-site hours reported

  7. Face ventilation control devices.

    violationRecord 5120653

    30 CFR 75.330(b)(2)

  8. Communications facilities; refuge alternatives.

    violationRecord 5120652

    30 CFR 75.1600-3(a)(2)

  9. Roof control plan.

    violationRecord 5120651

    30 CFR 75.220(a)(1) · Significant and substantial (S&S)

  10. Protection from falls of roof, face and ribs.

    violationRecord 5120650

    30 CFR 75.202(a) · Significant and substantial (S&S)

  11. Accumulation of combustible materials.

    violationRecord 5120649

    30 CFR 75.400

  12. Roof control plan.

    violationRecord 5120648

    30 CFR 75.220(a)(1)

  13. Spot Inspections

    inspectionRecord F0463D7

    103(i) · 8.0 on-site hours reported

  14. Auxiliary fans and tubing.

    violationRecord 5120647

    30 CFR 75.331(a)(4)

  15. Spot Inspections

    inspectionRecord F0463D6

    103(i) · 7.5 on-site hours reported

  16. Accumulation of combustible materials.

    violationRecord 5120646

    30 CFR 75.400

  17. Electric equipment; examination, testing and maintenance.

    violationRecord 5120645

    30 CFR 75.512

  18. Condition and examination of firefighting equipment.

    violationRecord 5120644

    30 CFR 75.1100-3

  19. Spot Inspections

    inspectionRecord F0463D5

    103(i) · 10.8 on-site hours reported

  20. Accumulation of combustible materials.

    violationRecord 5120643

    30 CFR 75.400

  21. Regular Safety and Health Inspection

    inspectionRecord F019991

    49.8 on-site hours reported

  22. Spot Inspections

    inspectionRecord F0166C9

    103(i) · 8.0 on-site hours reported

  23. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 8046856

    30 CFR 75.1731(a)

  24. Spot Inspections

    inspectionRecord F0166C8

    103(i) · 6.5 on-site hours reported

  25. Fire

    accidentRecord 220262250017

    Accident only

    Accident narrative

    A fire occurred in the gob of the active Headgate 4 longwall panel.

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.