← LITTLE EAGLE MINE NO 1

LITTLE EAGLE MINE NO 1 safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Protection from falls of roof, face and ribs.

    violationRecord 5026334

    30 CFR 75.202(a) · Significant and substantial (S&S) · $1,126.00 proposed penalty

  2. Approval of other fire suppression devices.

    violationRecord 5023452

    30 CFR 75.1107-13(g) · $151.00 proposed penalty

  3. Mine ventilation plan; submission and approval.

    violationRecord 5023451

    30 CFR 75.370(a)(1) · $245.00 proposed penalty

  4. Electric equipment; examination, testing and maintenance.

    violationRecord 5023450

    30 CFR 75.512 · $151.00 proposed penalty

  5. Mine ventilation plan; submission and approval.

    violationRecord 5023449

    30 CFR 75.370(a)(1) · $755.00 proposed penalty

  6. Spot Inspections

    inspectionRecord F02D0C9

    103(i) · 6.0 on-site hours reported

  7. Power wires and cables; insulation and protection.

    violationRecord 5026330

    30 CFR 75.517 · $226.00 proposed penalty

  8. Electric equipment; examination, testing and maintenance.

    violationRecord 5026328

    30 CFR 75.512 · $549.00 proposed penalty

  9. Regular Safety and Health Inspection

    inspectionRecord F02D0C8

    132.5 on-site hours reported

  10. Spot Inspections

    inspectionRecord 6321738

    103(i) · 4.0 on-site hours reported

  11. Spot Inspection

    inspectionRecord F007E15

    4.0 on-site hours reported

  12. Spot Inspections

    inspectionRecord F02D0C5

    103(i) · 5.0 on-site hours reported

  13. Spot Inspections

    inspectionRecord F00B81E

    103(i) · 8.0 on-site hours reported

  14. Spot Inspections

    inspectionRecord F00B81D

    103(i) · 8.0 on-site hours reported

  15. Non-Injury Accident Investigation

    inspectionRecord F00B81C

    2.5 on-site hours reported

  16. Air quality.

    violationRecord 9844181

    30 CFR 75.321(a)(1) · $1,037.00 proposed penalty

  17. Fall of roof or back

    accidentRecord 220252110002

    Accident only

    Accident narrative

    A unplanned roof fall occurred on the 2 North Mains at Break 47,in the #1 Entry , 120 Ft Inby Spad 3512. There was NO Injuries, did not affect ventilation or passage of persons. Fall is being dangered off and breaker timbers are being installed at all approaches. Fall Measures 80' Long , 18-20' wide , 6-10'high

  18. Regular Safety and Health Inspection

    inspectionRecord F02D0BB

    58.0 on-site hours reported

  19. Hazardous conditions and violations of mandatory health or safety standards; posting, correcting, and recording.

    violationRecord 9847565

    30 CFR 75.363(a) · $336.00 proposed penalty

  20. Violation — cited standard not reported

    violationRecord 5026321
  21. Regular Safety and Health Inspection

    inspectionRecord F00B80E

    52.8 on-site hours reported

  22. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 9849939

    30 CFR 75.1714-3(a) · $267.00 proposed penalty

  23. Regular Safety and Health Inspection

    inspectionRecord 6321696

    43.8 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.