GRAYMONT (PA) INC. PLEASANT GAP safety activity
MSHA violations, accident reports and inspections.
Safety activity
Examination of working places.
30 CFR 57.18002 · Significant and substantial (S&S)
Moving machine parts.
30 CFR 57.14107(a) · Significant and substantial (S&S)
Insulation and fittings for power wires and cables.
30 CFR 57.12008
Housekeeping.
30 CFR 57.20003(a)
Insulation and fittings for power wires and cables.
30 CFR 57.12008
Insulation and fittings for power wires and cables.
30 CFR 57.12008
Stationary grinding machines.
30 CFR 57.14115(b) · Significant and substantial (S&S)
Inspection.
30 CFR 57.4201(a)(1)
Insulation and fittings for power wires and cables.
30 CFR 57.12008
Housekeeping.
30 CFR 57.20003(a)
Housekeeping.
30 CFR 57.20003(a)
Correction of hazardous conditions.
30 CFR 57.3200
Smoking and open flames.
30 CFR 57.7805
Housekeeping.
30 CFR 57.20003(a)
Correction of dangerous conditions.
30 CFR 57.12030
Moving machine parts.
30 CFR 57.14107(a) · Significant and substantial (S&S)
Correction of dangerous conditions.
30 CFR 57.12030
Controls and switches.
30 CFR 57.12002
Regular Safety and Health Inspection
73.8 on-site hours reported
Compliance Follow-up Inspection
5.8 on-site hours reported
Compliance Follow-up Inspection
4.5 on-site hours reported
Compliance Follow-up Inspection
3.5 on-site hours reported
Access to stationary electrical equipment or switchgear.
30 CFR 56.12019
Trimming stockpile and muckpile faces.
30 CFR 56.9314 · Significant and substantial (S&S) · $398.00 proposed penalty
Electric substations and liquid storage facilities.
30 CFR 56.4130(a)(1)
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.