← Francisco Underground Pit

Francisco Underground Pit safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-28Database snapshot · 2026-10-28

Safety activity

  1. Spot Inspections

    inspectionRecord F039FD1

    103(i) · 0.0 on-site hours reported

  2. Mine ventilation plan; submission and approval.

    violationRecord 5014618

    30 CFR 75.370(a)(1) · Significant and substantial (S&S)

  3. Mine ventilation plan; submission and approval.

    violationRecord 9785639

    30 CFR 75.370(a)(1) · Significant and substantial (S&S)

  4. Accumulation of combustible materials.

    violationRecord 9780754

    30 CFR 75.400

  5. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9780753

    30 CFR 75.1731(b)

  6. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9780752

    30 CFR 75.1731(a) · Significant and substantial (S&S)

  7. Spot Inspections

    inspectionRecord F046F03

    103(i) · 0.0 on-site hours reported

  8. Mine ventilation plan; submission and approval.

    violationRecord 5014617

    30 CFR 75.370(a)(1) · Significant and substantial (S&S)

  9. Permissible electric face equipment; maintenance.

    violationRecord 5014616

    30 CFR 75.503 · Significant and substantial (S&S)

  10. Spot Inspections

    inspectionRecord F01B953

    103(i) · 6.8 on-site hours reported

  11. Transport of diesel fuel.

    violationRecord 9785638

    30 CFR 75.1906(b)

  12. On-shift examination.

    violationRecord 5014615

    30 CFR 75.362(a)(1)

  13. Accumulation of combustible materials.

    violationRecord 5014614

    30 CFR 75.400

  14. Fall of roof or back

    accidentRecord 220262870017

    Accident only

    Accident narrative

    A fall of roof occurred on the 8W Main belt, entry #5 between crosscut 151-152. The fall measured approx. 20-25' in length by 18' in width for a thickness of 12.5'.

  15. Non-Injury Accident Investigation

    inspectionRecord F01B954

    19.5 on-site hours reported

  16. Roof control plan.

    violationRecord 9785637

    30 CFR 75.220(a)(1)

  17. Violation — cited standard not reported

    violationRecord 9785636
  18. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 5014613

    30 CFR 75.1731(b)

  19. Ventilation controls.

    violationRecord 9785635

    30 CFR 75.333(b)(2)

  20. Mine ventilation plan; submission and approval.

    violationRecord 9785634

    30 CFR 75.370(a)(1) · Significant and substantial (S&S)

  21. Roof control plan.

    violationRecord 5014612

    30 CFR 75.220(a)(1)

  22. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 5014611

    30 CFR 75.1731(a)

  23. Spot Inspections

    inspectionRecord 7005304

    103(i) · 6.3 on-site hours reported

  24. Temporary notations, revisions, and supplements.

    violationRecord 9785633

    30 CFR 75.1202

  25. Methane monitors.

    violationRecord 9785632

    30 CFR 75.342(a)(4)

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.