← ENLOW FORK MINE

ENLOW FORK MINE safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Maintenance of incombustible content of rock dust.

    violationRecord 9604387

    30 CFR 75.403 · $151.00 proposed penalty

  2. Maintenance of incombustible content of rock dust.

    violationRecord 9604386

    30 CFR 75.403 · $151.00 proposed penalty

  3. Quantity and location of firefighting equipment.

    violationRecord 9601924

    30 CFR 75.1100-2(f) · $151.00 proposed penalty

  4. Handling of materials

    accidentRecord 220250850010

    Days away from work only

    Accident narrative

    Employee was loading supplies onto a roof bolter and felt pain in their back. Injury was not witnessed, and after an investigation, it was decided on 3/19/2025 that this could not be attributed to anything but the work activity the day of the report. Injury was not the result of a training or compliance issue.

  5. Underground electrical installations.

    violationRecord 9604486

    30 CFR 75.340(a)(1)(i) · $151.00 proposed penalty

  6. Ventilation controls.

    violationRecord 9603214

    30 CFR 75.333(h) · $151.00 proposed penalty

  7. Spot Inspections

    inspectionRecord F00A2BB

    103(i) · 3.3 on-site hours reported

  8. Roof control plan.

    violationRecord 9604550

    30 CFR 75.220(a)(1) · $209.00 proposed penalty

  9. Permissible electric face equipment; maintenance.

    violationRecord 9604549

    30 CFR 75.503 · $151.00 proposed penalty

  10. Power wires and cables; insulation and protection.

    violationRecord 9605513

    30 CFR 75.517 · $288.00 proposed penalty

  11. Ventilation controls.

    violationRecord 9605512

    30 CFR 75.333(h) · $226.00 proposed penalty

  12. Ventilation controls.

    violationRecord 9604485

    30 CFR 75.333(c)(3) · $151.00 proposed penalty

  13. Fall of roof or back

    accidentRecord 220250620019

    Days away from work only

    Accident narrative

    The employee was standing at the ATRS controls on a continuous miner when the employee was struck by a rock in the head and neck area. The employee received 13 sutures to the left ear lobe.

  14. Cable fittings; suitability.

    violationRecord 9604547

    30 CFR 75.515 · $193.00 proposed penalty

  15. Spot Inspections

    inspectionRecord F00A2BA

    103(i) · 4.5 on-site hours reported

  16. Ventilation controls.

    violationRecord 9604384

    30 CFR 75.333(h) · $151.00 proposed penalty

  17. Mine ventilation plan; submission and approval.

    violationRecord 9601923

    30 CFR 75.370(a)(1) · $151.00 proposed penalty

  18. Electric equipment; examination, testing and maintenance.

    violationRecord 9601922

    30 CFR 75.512 · $151.00 proposed penalty

  19. Identification of circuit breakers.

    violationRecord 9605511

    30 CFR 75.904 · $642.00 proposed penalty

  20. Ventilation controls.

    violationRecord 9603770

    30 CFR 75.333(c)(3) · $193.00 proposed penalty

  21. Belt air course ventilation.

    violationRecord 9604383

    30 CFR 75.350(a) · $151.00 proposed penalty

  22. Automatic fire sensor and warning device systems; installation; minimum requirements.

    violationRecord 9603173

    30 CFR 75.1103-4(b) · $151.00 proposed penalty

  23. Spot Inspections

    inspectionRecord 6229632

    103(i) · 5.0 on-site hours reported

  24. Machinery and equipment; operation and maintenance.

    violationRecord 9603769

    30 CFR 75.1725(a) · Significant and substantial (S&S) · $959.00 proposed penalty

  25. Storage of liquefied and nonliquefied compressed gas cylinders; requirements.

    violationRecord 9603768

    30 CFR 75.1106-3(a)(2) · $193.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.