← ENLOW FORK MINE

ENLOW FORK MINE safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Ventilation controls.

    violationRecord 9604401

    30 CFR 75.333(h) · $245.00 proposed penalty

  2. Spot Inspections

    inspectionRecord 6229782

    103(i) · 13.0 on-site hours reported

  3. Underground electrical installations.

    violationRecord 9601363

    30 CFR 75.340(a)(1)(i) · $755.00 proposed penalty

  4. Spot Inspections

    inspectionRecord F016F84

    103(i) · 4.0 on-site hours reported

  5. Accumulation of combustible materials.

    violationRecord 9605671

    30 CFR 75.400 · $151.00 proposed penalty

  6. Fall of roof or back

    accidentRecord 220251990024

    Accident only

    Accident narrative

    An unintentional roof fall occurred in 2 East Mains at 69 Wall, #4 to #5 Entry. The fall was approximately 8' high x 16' wide x 40' long. The immediate roof consisted of laminated shale type material; Adverse geological conditions contributed to the fall. No injuries occurred because of this incident and no compliance issues were found.

  7. Non-Injury Accident Investigation

    inspectionRecord 6229654

    10.0 on-site hours reported

  8. Short circuit protection; ratings and settings of circuit breakers.

    violationRecord 9601362

    30 CFR 75.601-1 · $151.00 proposed penalty

  9. Spot Inspections

    inspectionRecord 6229653

    103(i) · 6.0 on-site hours reported

  10. Electric equipment; examination, testing and maintenance.

    violationRecord 9604477

    30 CFR 75.512 · $151.00 proposed penalty

  11. Quantity and location of firefighting equipment.

    violationRecord 9604476

    30 CFR 75.1100-2(f) · $151.00 proposed penalty

  12. Drill dust control at underground areas of underground mines.

    violationRecord 5156617

    30 CFR 72.630(b) · $288.00 proposed penalty

  13. Roof control plan.

    violationRecord 5156616

    30 CFR 75.220(a)(1) · $209.00 proposed penalty

  14. Fall of roof or back

    accidentRecord 220251980017

    Accident only

    Accident narrative

    An unintentional roof fall occurred in 3 North 113 Wall #9 Entry. The fall was approximately 16' high x 16' wide x 50' long. The immediate roof consisted of laminated shale type material; Adverse geological conditions contributed to the fall. No injuries occurred because of this incident and no compliance issues were found.

  15. Non-Injury Accident Investigation

    inspectionRecord F00BB50

    10.5 on-site hours reported

  16. Ventilation Technical Investigation

    inspectionRecord 6229781

    35.0 on-site hours reported

  17. Violation — cited standard not reported

    violationRecord 5156615
  18. Regular Safety and Health Inspection

    inspectionRecord 6229652

    1,096.0 on-site hours reported

  19. Spot Inspections

    inspectionRecord F00A2C2

    103(i) · 7.0 on-site hours reported

  20. Spot Inspections

    inspectionRecord F00A2C1

    103(i) · 7.5 on-site hours reported

  21. Mine ventilation plan; submission and approval.

    violationRecord 9604397

    30 CFR 75.370(a)(1) · $226.00 proposed penalty

  22. Methane monitors.

    violationRecord 9604396

    30 CFR 75.342(a)(4) · $151.00 proposed penalty

  23. Underground electrical installations.

    violationRecord 5156611

    30 CFR 75.340(a)(1)(i) · Significant and substantial (S&S) · $3,184.00 proposed penalty

  24. Permissible electric face equipment; maintenance.

    violationRecord 5156610

    30 CFR 75.503 · $151.00 proposed penalty

  25. Spot Inspections

    inspectionRecord F00A2C0

    103(i) · 6.5 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.