Delbarton Preparation Plant safety activity
MSHA violations, accident reports and inspections.
Safety activity
Cable fittings; suitability.
30 CFR 77.505
Quantity and location of firefighting equipment.
30 CFR 77.1109(c)(1)
Machinery and equipment; operation and maintenance.
30 CFR 77.404(a)
Travelways at surface installations.
30 CFR 77.205(a)
Travelways at surface installations.
30 CFR 77.205(a)
Travelways at surface installations.
30 CFR 77.205(a)
Minimum requirements for bathing facilities, change rooms, and sanitary flush toilet facilities.
30 CFR 71.402(a)
Travelways at surface installations.
30 CFR 77.205(b)
Surface installations; general.
30 CFR 77.200
Mechanical equipment guards.
30 CFR 77.400(d)
Loading and haulage equipment; inspection and maintenance.
30 CFR 77.1606(c)
Highwalls, pits and spoil banks; plans.
30 CFR 77.1000
Regular Safety and Health Inspection
35.3 on-site hours reported
Spot Inspection
9.3 on-site hours reported
Sanitary toilet facilities; maintenance.
30 CFR 71.501
Handtools (nonpowered)
Days away from work only
Accident narrative
Employee was helping splice a belt, while one employee was swinging a hammer nailing the splice. EE thought the other employee had stopped hammering and extended EE's hand to move the anvil over and was struck with a 4-pound hammer. EE suffered a fractured left ring finger; EE was taken to PMC hospital and had surgery to repair the fracture.
Spot Inspection
1.8 on-site hours reported
Verbal Hazard Complaint Inspections
17.8 on-site hours reported
Travelways at surface installations.
30 CFR 77.205(b) · Significant and substantial (S&S)
Travelways at surface installations.
30 CFR 77.205(a) · Significant and substantial (S&S)
Mechanical equipment guards.
30 CFR 77.400(a) · Significant and substantial (S&S)
Travelways at surface installations.
30 CFR 77.205(b) · Significant and substantial (S&S)
Loading and haulage equipment; inspection and maintenance.
30 CFR 77.1606(c)
Impoundment Spot Inspection
3.0 on-site hours reported
Water, sediment, or slurry impoundments and impounding structures; general.
30 CFR 77.216(d) · $151.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.