← CARDINAL

CARDINAL safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Mine ventilation plan; submission and approval.

    violationRecord 5046916

    30 CFR 75.370(a)(1)

  2. Belt air course ventilation.

    violationRecord 5048095

    30 CFR 75.350(a)(2)

  3. Spot Inspections

    inspectionRecord F02087D

    103(i) · 9.0 on-site hours reported

  4. Methane monitors.

    violationRecord 5046915

    30 CFR 75.342(a)(4) · Significant and substantial (S&S)

  5. Ventilation controls.

    violationRecord 5048094

    30 CFR 75.333(h)

  6. Escapeway maps.

    violationRecord 5048093

    30 CFR 75.1505(b)

  7. Ventilation controls.

    violationRecord 5048092

    30 CFR 75.333(h)

  8. Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.

    violationRecord 9760832

    30 CFR 75.1714-3(a) · $151.00 proposed penalty

  9. Maintenance of diesel-powered equipment.

    violationRecord 9760831

    30 CFR 75.1914(a) · $151.00 proposed penalty

  10. Spot Inspections

    inspectionRecord F02087B

    103(i) · 8.0 on-site hours reported

  11. Methane monitors.

    violationRecord 5046914

    30 CFR 75.342(a)(4) · Significant and substantial (S&S) · $755.00 proposed penalty

  12. Cable fittings; suitability.

    violationRecord 5047735

    30 CFR 75.515 · $151.00 proposed penalty

  13. Permissible electric face equipment; maintenance.

    violationRecord 5047734

    30 CFR 75.503 · $151.00 proposed penalty

  14. Accumulation of combustible materials.

    violationRecord 5047042

    30 CFR 75.400 · $366.00 proposed penalty

  15. Electric equipment; examination, testing and maintenance.

    violationRecord 5046913

    30 CFR 75.512 · $313.00 proposed penalty

  16. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 5046755

    30 CFR 75.1103-8(c) · $151.00 proposed penalty

  17. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 5046754

    30 CFR 75.1103-8(c) · $151.00 proposed penalty

  18. Automatic fire sensor and warning device systems; examination and test requirements.

    violationRecord 5046753

    30 CFR 75.1103-8(c) · $151.00 proposed penalty

  19. Preshift examination at fixed intervals.

    violationRecord 5045795

    30 CFR 75.360(a)(1) · Significant and substantial (S&S)

  20. Protection from falls of roof, face and ribs.

    violationRecord 5045794

    30 CFR 75.202(a)

  21. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 5045793

    30 CFR 75.1731(b)

  22. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 5045792

    30 CFR 75.1731(a)

  23. Accumulation of combustible materials.

    violationRecord 5045791

    30 CFR 75.400 · Significant and substantial (S&S)

  24. Slip or fall of person

    accidentRecord 220262530011

    Days away from work only

    Accident narrative

    Employee was stepping down from a 30" bank at the 6B header resulting in a strained back. EE is being treated for sciatica.

  25. Spot Inspections

    inspectionRecord F00AE98

    103(i) · 14.8 on-site hours reported

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.