Calvary No 81 safety activity
MSHA violations, accident reports and inspections.
Safety activity
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · Significant and substantial (S&S) · $1,320.00 proposed penalty
Roof testing and scaling.
30 CFR 75.211(c) · $151.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $755.00 proposed penalty
Loading and haulage equipment; inspection and maintenance.
30 CFR 77.1606(c) · $209.00 proposed penalty
Automatic fire warning devices; actions and response.
30 CFR 75.1103-5(a)(1) · $151.00 proposed penalty
Ventilation controls.
30 CFR 75.333(b)(3) · $151.00 proposed penalty
Quantity and location of firefighting equipment.
30 CFR 75.1100-2(b) · $151.00 proposed penalty
Quantity and location of firefighting equipment.
30 CFR 75.1100-2(e) · $151.00 proposed penalty
Preshift examination at fixed intervals.
30 CFR 75.360(g) · $151.00 proposed penalty
Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.
30 CFR 75.1600-2(b) · $151.00 proposed penalty
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · $151.00 proposed penalty
Installation of high-voltage transmission cables.
30 CFR 75.807 · $151.00 proposed penalty
Regular Safety and Health Inspection
425.0 on-site hours reported
Spot Inspection
54.5 on-site hours reported
Slip or fall of person
No dys awy frm wrk,no rstr act
Accident narrative
EE was scattering structure when EE tripped over a roller. As EE fell, the stand that EE had landed on EE's legs.
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · $193.00 proposed penalty
Non-Injury Accident Investigation
22.5 on-site hours reported
Violation — cited standard not reported
Belt air course ventilation.
30 CFR 75.350(a)(2) · $151.00 proposed penalty
Maintenance of belt conveyors and belt conveyor entries.
30 CFR 75.1731(b) · $151.00 proposed penalty
Condition and examination of firefighting equipment.
30 CFR 75.1100-3 · $151.00 proposed penalty
Smoking programs.
30 CFR 75.1702-1 · $151.00 proposed penalty
Automatic fire sensor and warning device systems; examination and test requirements.
30 CFR 75.1103-8(c) · $151.00 proposed penalty
Protection of trailing cables.
30 CFR 75.606 · $177.00 proposed penalty
Ventilation controls.
30 CFR 75.333(c)(3) · $177.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.