Calvary No 81 safety activity
MSHA violations, accident reports and inspections.
Safety activity
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $549.00 proposed penalty
Violation — cited standard not reported
Fall of roof or back
Accident only
Accident narrative
A non-injury roof fall occurred on the Pigeonroost Mains in by x-cut 43. The fall was approximately 16' x 20' x 3'. This was a result of deterioration in a transition zone from sandstone to shale.
Other safeguards.
30 CFR 75.1403
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $151.00 proposed penalty
Mechanical equipment guards.
30 CFR 77.400(a) · $151.00 proposed penalty
Drill dust control at underground areas of underground mines.
30 CFR 72.630(b) · $177.00 proposed penalty
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1) · $177.00 proposed penalty
Additional self-contained self-rescuers (SCSRs).
30 CFR 75.1714-4(b) · $151.00 proposed penalty
Automatic fire warning devices; actions and response.
30 CFR 75.1103-5(h) · $151.00 proposed penalty
Powered haulage
No dys awy frm wrk,no rstr act
Accident narrative
EE was on one knee at the lolo and attempted to stand up. As EE placed EE's right hand on the lolo top rail to steady self, EE did not realize that the belt guide rail was so close to EE's hand. The belt guide wheel caught the thumb on EE's right hand. EE did seek medical treatment where EE received stitches in EE's thumb. EE has not missed any work.
Identification of circuit breakers.
30 CFR 75.904 · $151.00 proposed penalty
Mining methods.
30 CFR 75.203(a) · $151.00 proposed penalty
Belt air course ventilation.
30 CFR 75.350(a)(2) · $151.00 proposed penalty
Power wires and cables; insulation and protection.
30 CFR 75.517 · Significant and substantial (S&S) · $818.00 proposed penalty
Accumulation of combustible materials.
30 CFR 75.400 · $151.00 proposed penalty
Ventilation controls.
30 CFR 75.333(b)(2) · $151.00 proposed penalty
Automatic fire warning devices; actions and response.
30 CFR 75.1103-5(h) · $151.00 proposed penalty
Main mine fan examinations and records.
30 CFR 75.312(f)(1) · $151.00 proposed penalty
Permissible electric face equipment; maintenance.
30 CFR 75.503 · $151.00 proposed penalty
Electric equipment; examination, testing and maintenance.
30 CFR 75.512 · $151.00 proposed penalty
Quantity and location of firefighting equipment.
30 CFR 75.1100-2(f) · $151.00 proposed penalty
Ventilation controls.
30 CFR 75.333(d)(3) · $151.00 proposed penalty
Ventilation controls.
30 CFR 75.333(b)(3) · $151.00 proposed penalty
Regular Safety and Health Inspection
281.3 on-site hours reported
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.