Calvary No 81 safety activity
MSHA violations, accident reports and inspections.
Safety activity
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(6)
Mine ventilation plan; submission and approval.
30 CFR 75.370(a)(1)
Belt air course ventilation.
30 CFR 75.350(a)(2)
Maintenance of belt conveyors and belt conveyor entries.
30 CFR 75.1731(a) · Significant and substantial (S&S)
Inspection of fire suppression devices.
30 CFR 75.1107-16(c)
Accumulation of combustible materials.
30 CFR 75.400
Accumulation of combustible materials.
30 CFR 75.400
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(7)(vi)
Inspection of fire suppression devices.
30 CFR 75.1107-16(b)
Maintenance of belt conveyors and belt conveyor entries.
30 CFR 75.1731(a)
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(7)(i)
Automatic fire warning devices; actions and response.
30 CFR 75.1103-5(a)(1)
Electric equipment; switches.
30 CFR 75.520
Machinery and equipment; operation and maintenance.
30 CFR 75.1725(a) · Significant and substantial (S&S)
Escapeways; bituminous and lignite mines.
30 CFR 75.380(d)(7)(vi)
Electric equipment; examination, testing and maintenance.
30 CFR 75.512
Regular Safety and Health Inspection
119.0 on-site hours reported
Roof control plan.
30 CFR 75.220(a)(1) · Significant and substantial (S&S)
Spot Inspection
8.0 on-site hours reported
Spot Inspection
7.0 on-site hours reported
Fall of roof or back
Accident only
Accident narrative
Deterioration of the roof in a transition zone from sandstone to shale. This fell in the belt line entry and there were no negative impacts on air or the travel entries. .
Non-Injury Accident Investigation
31.8 on-site hours reported
Protection from falls of roof, face and ribs.
30 CFR 75.202(a) · Significant and substantial (S&S) · $697.00 proposed penalty
Violation — cited standard not reported
Non-Injury Accident Investigation
12.0 on-site hours reported
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.