← Bailey Mine

Bailey Mine safety activity

MSHA violations, accident reports and inspections.

2025-01-01 – 2026-10-31Database snapshot · 2026-10-31

Safety activity

  1. Fall of roof or back

    accidentRecord 220250340022

    Accident only

    Accident narrative

    An unintentional roof fall occurred in 6 south area of the mine at 102 xcut in the #5 entry (Track). This fall measured 18ft long by 8ft high by 50 ft wide. The fall was caused by adverse roof conditions in the form of laminated shale that separated above the anchorage point.

  2. Non-Injury Accident Investigation

    inspectionRecord F00BB49

    10.5 on-site hours reported

  3. Violation — cited standard not reported

    violationRecord 9604534
  4. Other safeguards.

    violationRecord 9604305

    30 CFR 75.1403 · $165.00 proposed penalty

  5. Fire suppression devices; approved components; installation requirements.

    violationRecord 9604304

    30 CFR 75.1107-3(d) · $151.00 proposed penalty

  6. Cable fittings; suitability.

    violationRecord 9604303

    30 CFR 75.515 · $151.00 proposed penalty

  7. Maintenance of incombustible content of rock dust.

    violationRecord 9604302

    30 CFR 75.403 · $151.00 proposed penalty

  8. Accumulation of combustible materials.

    violationRecord 9601874

    30 CFR 75.400 · $177.00 proposed penalty

  9. Permissible electric face equipment; maintenance.

    violationRecord 9601873

    30 CFR 75.503 · $151.00 proposed penalty

  10. Dry chemical devices; capacity; minimum requirements.

    violationRecord 9601872

    30 CFR 75.1107-9(a)(1) · $151.00 proposed penalty

  11. Spot Inspections

    inspectionRecord F011F88

    103(i) · 4.0 on-site hours reported

  12. Electric equipment; examination, testing and maintenance.

    violationRecord 9604533

    30 CFR 75.512 · $313.00 proposed penalty

  13. Escapeways; bituminous and lignite mines.

    violationRecord 9604300

    30 CFR 75.380(d)(7)(iv) · $151.00 proposed penalty

  14. Mine ventilation plan; submission and approval.

    violationRecord 9603211

    30 CFR 75.370(a)(1) · $151.00 proposed penalty

  15. Maintenance of incombustible content of rock dust.

    violationRecord 9603170

    30 CFR 75.403 · $151.00 proposed penalty

  16. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9601871

    30 CFR 75.1731(a) · $151.00 proposed penalty

  17. Maintenance of belt conveyors and belt conveyor entries.

    violationRecord 9601870

    30 CFR 75.1731(b) · $151.00 proposed penalty

  18. Slip or fall of person

    accidentRecord 220250660019

    Days away from work only

    Accident narrative

    At #6 EE was parked beside the refuse shop. EE exited EE's pickup truck to take supplies to a truck driver that was in line at the bin. When walking back to EE's truck EE slipped on the ice and fell backward onto back. When EE fell EE's hardhat came off and ended up under EE's top of back/neck area. Employee did not miss work until 2/23/2025.

  19. Electric equipment; examination, testing and maintenance.

    violationRecord 9604532

    30 CFR 75.512 · Significant and substantial (S&S) · $5,144.00 proposed penalty

  20. Ventilation controls.

    violationRecord 9604531

    30 CFR 75.333(h) · $313.00 proposed penalty

  21. Roof control plan.

    violationRecord 9604530

    30 CFR 75.220(a)(1) · $267.00 proposed penalty

  22. Roof control plan.

    violationRecord 9604529

    30 CFR 75.220(a)(1) · $267.00 proposed penalty

  23. Quantity and location of firefighting equipment.

    violationRecord 9604299

    30 CFR 75.1100-2(f) · $245.00 proposed penalty

  24. Maintenance of incombustible content of rock dust.

    violationRecord 9604298

    30 CFR 75.403 · $151.00 proposed penalty

  25. Daily examination of hoisting equipment.

    violationRecord 9603765

    30 CFR 77.1403 · $504.00 proposed penalty

Sources and definitions

MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).

Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.

Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.

Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.

S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.

Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.

Portfolio totals use current mine membership, including events before the current owner or operator's tenure.