Amrize Portland Plant safety activity
MSHA violations, accident reports and inspections.
Safety activity
Slip or fall of person
Days away from work only
Accident narrative
Two employees working on the pier 2 south side of the kiln removing a guard. The guard become stuck and one employee pulled on it and it came loose causing employee to fall backwards hitting EE's head on handrail or toe kick causing a laceration requiring 3 staples.
Compliance Follow-up Inspection
3.0 on-site hours reported
Entrapment
Accident only
Accident narrative
Clinker Silo elevator become disabled approximately 130' with a contractor scaffolding employee in the elevator. The call to supervisor and safety was made. Employee was not injured and was doing ok communication by radio and cell phone. Employee was safely taken to the ground with a 150" manlift with no injuries or further incident.
Records of training.
30 CFR 46.9(c)(1) · $151.00 proposed penalty
Inspection and cover plates.
30 CFR 56.12032 · $209.00 proposed penalty
Identification of power switches.
30 CFR 56.12018 · $209.00 proposed penalty
Housekeeping.
30 CFR 56.20003(b) · $209.00 proposed penalty
Splices and repairs of power cables.
30 CFR 56.12013(b) · $209.00 proposed penalty
Electrical conductors.
30 CFR 56.12004 · Significant and substantial (S&S) · $465.00 proposed penalty
Protection of power conductors from mobile equipment.
30 CFR 56.12005 · $209.00 proposed penalty
Requirement for container labels.
30 CFR 47.41(a) · $151.00 proposed penalty
Identification of power switches.
30 CFR 56.12018 · $209.00 proposed penalty
Protection of gas cylinder valves.
30 CFR 56.16006 · $209.00 proposed penalty
Training plans.
30 CFR 46.3(b)(4) · $151.00 proposed penalty
Records of training.
30 CFR 46.9(b)(5) · $151.00 proposed penalty
Records of training.
30 CFR 46.9(b)(2) · $151.00 proposed penalty
Parking procedures for unattended equipment.
30 CFR 56.14207 · $151.00 proposed penalty
Housekeeping.
30 CFR 56.20003(a) · $697.00 proposed penalty
Safety defects; examination, correction and records.
30 CFR 56.14100(b) · $209.00 proposed penalty
Illumination of surface working areas.
30 CFR 56.17001 · $245.00 proposed penalty
Identification of power switches.
30 CFR 56.12018 · $245.00 proposed penalty
Housekeeping.
30 CFR 56.20003(a) · $818.00 proposed penalty
Unguarded conveyors with adjacent travelways.
30 CFR 56.14109(a) · $366.00 proposed penalty
Dust control.
30 CFR 56.9315 · $245.00 proposed penalty
Moving machine parts.
30 CFR 56.14107(a) · Significant and substantial (S&S) · $1,219.00 proposed penalty
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.