Titan Cement International S A safety activity
MSHA violations, accident reports and inspections across the current mine portfolio.
Safety activity
Warning signs.
PENNSUCO QUARRY · 080093130 CFR 56.4101 · $151.00 proposed penalty
Warning signs.
PENNSUCO QUARRY · 080093130 CFR 56.4101 · $151.00 proposed penalty
Warning signs.
PENNSUCO QUARRY · 080093130 CFR 56.4101 · $818.00 proposed penalty
Warning signs.
PENNSUCO QUARRY · 080093130 CFR 56.4101 · $151.00 proposed penalty
General requirements.
PENNSUCO QUARRY · 080093130 CFR 56.4200(b)(2) · $151.00 proposed penalty
General requirements.
PENNSUCO QUARRY · 080093130 CFR 56.4200(b)(2) · $818.00 proposed penalty
Requirement for container labels.
PENNSUCO QUARRY · 080093130 CFR 47.41(a) · $1,219.00 proposed penalty
Safety can use.
PENNSUCO QUARRY · 080093130 CFR 56.4402 · $818.00 proposed penalty
Requirement for container labels.
PENNSUCO QUARRY · 080093130 CFR 47.41(a) · $1,219.00 proposed penalty
Securing gas cylinders.
PENNSUCO QUARRY · 080093130 CFR 56.16005 · $151.00 proposed penalty
Safe access.
PENNSUCO QUARRY · 080093130 CFR 56.11001 · $151.00 proposed penalty
Operators stations.
PENNSUCO QUARRY · 080093130 CFR 56.14103(b) · Significant and substantial (S&S) · $366.00 proposed penalty
Correction of dangerous conditions.
PENNSUCO QUARRY · 080093130 CFR 56.12030 · $193.00 proposed penalty
Regular Safety and Health Inspection
PENNSUCO QUARRY · 080093170.5 on-site hours reported
Spot Inspection
PENNSUCO QUARRY · 08009313.5 on-site hours reported
Powered haulage
PENNSUCO QUARRY · 0800931No dys awy frm wrk,no rstr act
Accident narrative
Associate was assisting in track maintenance near the switch stand, when the backhoe pressed against the switch point, causing the switch handle to swing in the opposite direction striking the associate in the side of EE's face and ear.
Safety defects; examination, correction and records.
New Castle Sand Plant · 440240230 CFR 56.14100(b) · $151.00 proposed penalty
Operators stations.
New Castle Sand Plant · 440240230 CFR 56.14103(a) · $151.00 proposed penalty
Identification of power switches.
New Castle Sand Plant · 440240230 CFR 56.12018 · $151.00 proposed penalty
Horns and backup alarms.
New Castle Sand Plant · 440240230 CFR 56.14132(b)(2) · $151.00 proposed penalty
Inspection and cover plates.
New Castle Sand Plant · 440240230 CFR 56.12032 · $151.00 proposed penalty
Circuit overload protection.
New Castle Sand Plant · 440240230 CFR 56.12001 · Significant and substantial (S&S) · $226.00 proposed penalty
Regular Safety and Health Inspection
New Castle Sand Plant · 440240232.0 on-site hours reported
Machinery
ROANOKE CEMENT COMPANY · 4400068Days restricted activity only
Accident narrative
Employee was attempting to blow off a turntable in the packhouse between the grate using an air lance. As the employee was pulling the air lance from the grate they felt a sharp pain in the right shoulder. The employee received medical attention, and been place on restricted duties.
Verbal Hazard Complaint Inspections
PENNSUCO CEMENT PLANT · 08000513.0 on-site hours reported
Sources and definitions
MSHA Violations (issue date), Accidents (accident date) and Inspections (begin date).
Violation titles use current CFR headings to identify the cited rule; they are not the inspector’s account of what happened.
Status is from the current MSHA Mines snapshot, not the selected reporting period. Closed records can retain their last reported controller/operator.
Counts describe published rows, including contractor records; accident records are not distinct incidents or numbers of people injured.
Zero means no matching records in the imported sources, not proof of no events. Historical coverage differs by source; absence before a source begins reporting is not a zero incident rate. Invalid or absent dates and records after the snapshot are excluded.
S&S means SIG_SUB=Y. Fatality records use DEGREE_INJURY_CD=01. Proposed penalties are not final assessed or paid amounts; missing dollar values are omitted.
Inspection hours are SUM_TOTAL_ON_SITE_HOURS attributed to the inspection start date, without supervisor/trainee hours. Missing hours are omitted; a started inspection may still be open.
Portfolio totals use current mine membership, including events before the current owner or operator's tenure.